NIIN Output Data
NIIN:
NSN:
Item Name:
VALVE , SAFETY RELIEF
Definition:
A VALVE DESIGNED TO AUTOMATICALLY RELEASE EXCESSIVE PRESSURES. IT IS ACTUATED BY STATIC PRESSURE UPSTREAM OF THE VALVE AND IS USED AS A SAFETY VALVE OR RELIEF VALVE, AND MAY BE SET TO CLOSE AT A PREDETERMINED PRESSURE. IT IS NOT DESIGNED FOR REGULATION OF CONTINUOUSLY FLUCTUATING LOADS. IT MAY BE INLINE OR CARTRIDGE (MANIFOLD) DESIGN. EXCLUDES VALVE (1), RELIEF, PRESSURE AND TEMPERATURE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
R670-1-1/4D2P | 86768 | H | 5 | 9 | E | AX | ||
R6701-1-1/4S2P | 86768 | H | 5 | 9 | E | AX | ||
R6701-1-1/4S2 | 86768 | H | 3 | 9 | 6 | ZZ |
CAGE Information
Code | Company |
---|---|
86768 | TELEDYNE INDUSTRIES INC TELEDYNE FLU |
Federal Supply Class
Title
VALVES, NONPOWERED
Inclusions:
INCLUDES AUTOMATIC NONPOWERED VALVES; GATE, GLOBE, ANGLE, CHECK, AND RELIEF VALVES; COCKS.
Exclusions:
EXCLUDES FIRE HYDRANTS (FSC 4210); SPRINKLER HEADS (FSC 4210); VALVES SPECIFICALLY DESIGNED FOR USE WITH FIRE FIGHTING EQUIPMENT (FSC 4210); PLUMBING EQUIPMENT, AND THE LIKE (FSC 4540).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AQLR | VALVE OPERATION METHOD | AUTOMATIC |
ADQU | FLOW CONTROL DEVICE | DISK |
CQCY | ADJUSTABLE PRESSURE RANGE | +1000.0/+1200.0 POUNDS PER SQUARE INCH |
AZGM | MOUNTING FACILITY | PANEL |