NIIN Output Data
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
734444-91 | 05869 | A | 5 | 2 | A | KZ | ||
734444-91 | 28427 | A | 5 | 2 | 5 | KZ | ||
734444-91 | 05973 | F | 5 | 2 | 5 | KZ | ||
734444-91 | 92607 | A | 5 | 2 | 5 | KZ | ||
734444-91 | 04569 | A | 3 | 2 | 5 | KZ | ||
EC20U4-2U | 81349 | M | 4 | 1 | E | KZ | ||
734444-91 | 24027 | A | 5 | 2 | 5 | KZ | ||
734444-91 | 12515 | A | 5 | 2 | 5 | KZ | ||
MIL-C-55021/2 | 81349 | M | 4 | 1 | E | KZ |
CAGE Information
Code | Company |
---|---|
04569 | NATIONAL WIRE AND CABLE CORPORATION |
05869 | RAYTHEON COMPANY DBA RAYTHEON |
28427 | BARCEL/CDT |
05973 | CHAMPLAIN CABLE CORP SUB OF HUBER AN |
92607 | TENSOLITE LLC DBA CARLISLE INTERCONN |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
24027 | CALMONT ENGINEERING & ELECTRONICS CO |
12515 | NEXANS USA INC. DBA NEXANS BERK TEK |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | TWIST |
AMQN | CONDUCTOR QUANTITY | 2 |
SFTT | SURFACE TREATMENT | SILVER CORE CONDUCTOR ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 TWISTED TOGETHER W/NO OUTER COVERING |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B298 FED SPEC SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC POLYTETRAFLUOROETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B298 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
ADVN | CROSS-SECTIONAL HEIGHT | 0.058 INCHES NOMINAL |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 20 AWG ALL CONDUCTORS |
ABJH | TEMP RATING | -65.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY STRAND QUANTITY PER CONDUCTOR AND STRAND AWG SIZE PER CONDUCTOR |
ADWH | CROSS-SECTIONAL WIDTH | 0.116 INCHES NOMINAL |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |