NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
A314XBX48PL-120VAC | 00213 | A | 5 | 2 | E | ZZ | ||
103166-001 | 54933 | A | 5 | 2 | 5 | ZZ | ||
CAD11A10/110 | 58219 | A | 5 | 2 | E | TX | ||
KRPA11AN-120 | 77342 | A | 3 | 2 | E | TX | ||
886-0658 | 83330 | A | 5 | 9 | 5 | TX | ||
CAD-11A10/110VAC | 32609 | A | 3 | 9 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
00213 | STRUTHERS-DUNN LLC |
54933 | AERO SYSTEMS ENGINEERING INC. DBA AS |
58219 | OMNTEC MFG. INC. |
77342 | TYCO ELECTRONICS CORPORATION |
83330 | DIALIGHT CORPORATION |
32609 | MONACO ENTERPRISES INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
ABHP | OVERALL LENGTH | 1.410 INCHES MAXIMUM |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 17.5 MILLIAMPERES AC SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
ABKW | OVERALL HEIGHT | 2.000 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 50.0 MINIMUM AND 60.0 MAXIMUM |
APNA | WINDING DC RESISTANCE RATING | 2.25 KILOHMS NOMINAL SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
AGAV | END ITEM IDENTIFICATION | 6635-00-361-4591 MAGNETIC INSPECTION UNIT,STATIONARY |
ADTV | CASE MATERIAL | PLASTIC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
APNQ | ARC QUENCHING METHOD | AIR |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APNP | DUTY TYPE | CONTINUOUS |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
ABMK | OVERALL WIDTH | 1.410 INCHES MAXIMUM |
CRXH | TIME DELAY | 0.015 SECONDS NOMINAL FIXED OPERATE TIME |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC |
TTQY | TERMINAL TYPE AND QUANTITY | 1 STANDARD TUBE BASE ALL FUNCTIONS |
CBME | CUBIC MEASURE | 3.976 CUBIC INCHES |
CRXH | TIME DELAY | 0.01 SECONDS NOMINAL FIXED RELEASE TIME |