NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
L04037 | 16236 | A | 3 | 2 | 5 | TX | ||
KGU2301-1 | 02750 | A | 5 | 9 | A | TX | ||
KGU2301-1 | 06RP6 | A | 3 | 1 | 1 | ZZ |
CAGE Information
Code | Company |
---|---|
02750 | EATON AEROSPACE LLC DIV ELECTRICAL S |
16236 | DLA LAND AND MARITIME |
06RP6 | DRS CONSOLIDATED CONTROLS, INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADAR | BODY OUTSIDE DIAMETER | 1.390 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 7.07 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ADAQ | BODY LENGTH | 0.700 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DESC PRODUCTION STANDARD NO. L04037; FOR NAVY NUCLEAR PROPULSION PLANT PRODUCTS ONLY |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 9 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 7.07 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 12.73 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 14.14 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 5.0 VOLT-AMPERE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL SINGLE COMPONENT |