NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
625-5749101 FIND 5 | 50079 | A | 5 | 9 | 5 | TX | ||
KD-J2A | 58657 | A | 3 | 2 | E | TX | ||
K161-1 | 36378 | R | C | 1 | 6 | ZZ | AC |
CAGE Information
Code | Company |
---|---|
36378 | RAYTHEON TECHNICAL SERVICES COMPANY |
50079 | TEXTRON INC. DBA TEXTRON MARINE & LA |
58657 | LEACH INTERNATIONAL CORPORATION DBA |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 29.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
APCN | COIL QUANTITY | 1 |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES AC INDUCTIVE LOAD AND 12.0 AMPERES DC INDUCTIVE LOAD |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 11 WIRE HOOK ALL FUNCTIONS |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
CRXH | TIME DELAY | 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 SLOTTED HOLE SINGLE MOUNTING FACILITY |
APNP | DUTY TYPE | CONTINUOUS |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
ABKW | OVERALL HEIGHT | 1.015 INCHES NOMINAL |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 MILLIAMPERES AC LAMP LOAD AND 500.0 MILLIAMPERES DC LAMP LOAD |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.000 INCHES NOMINAL |
APNA | WINDING DC RESISTANCE RATING | 290.0 OHMS NOMINAL SINGLE WINDING |
AGAV | END ITEM IDENTIFICATION | CONTROL UNIT |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC INDUCTIVE LOAD AND 1.0 AMPERES DC INDUCTIVE LOAD |
Similar Parts
K161-1 ,
K1611 ,
5945-01-289-4174 ,
5945012894174 ,
012894174
,
625-5749101 FIND 5 ,
KD-J2A ,
K161-1 ,