Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
TRANSFORMER , POWER , VIBRATOR

Definition:

A TRANSFORMER CONSISTING OF TWO OR MORE WINDINGS DESIGNED FOR USE WITH A VIBRATOR FOR STEPPING UP OR DOWN PULSATING DIRECT CURRENT VOLTAGES. MAY ALSO HAVE PROVISIONS FOR ALTERNATING CURRENT INPUT VOLTAGES. EXCLUDES TRANSFORMER, PULSE.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
CT103830 98330 A 5 2 6 TX
2916253-3 10001 A 3 2 A TX
DB100812 25656 A 5 2 6 TX
03049 15634 A 5 2 6 TX

CAGE Information

Code Company
10001 NAVAIR AND NAVSEA MANAGED ORIGINAL D
98330 OECO, LLC
25656 DBP MICROWAVE INC. DBA
15634 MAGNETIKA INC

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
TEST TEST DATA DOCUMENT 10001-2916253 DRAWING
AKNA INCLOSURE TYPE FULLY INCLOSED
THSD THREAD SERIES DESIGNATOR UNC SINGLE GROUP
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 188.0 GRAMS
ABKW OVERALL HEIGHT 1.750 INCHES MAXIMUM
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.802 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 0.822 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 450.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) CENTER TAP SINGLE COMPONENT ALL SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 0.990 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 3.6 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
ACZB FREQUENCY RATING 15.0 KILOHERTZ NOMINAL SINGLE COMPONENT
CQJX NOMINAL THREAD SIZE 0.112 INCHES SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 39.59 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CWJS WINDING OPERATING VOLTAGE 111.35 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 5.30 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 106.05 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 10.61 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 116.66 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
ADAQ BODY LENGTH 1.500 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 17.68 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AEHZ MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS
TTQY TERMINAL TYPE AND QUANTITY 14 TAB, SOLDER LUG
CRBZ WINDING OPERATING CURRENT 15.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
ADAT BODY WIDTH 1.250 INCHES MAXIMUM

Similar Parts

2916253-3 , 29162533 , 5950-01-307-7603 , 5950013077603 , 013077603 , CT103830 , 2916253-3 , DB100812 , 03049 ,