NIIN Output Data
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K7089 | 51181 | A | 5 | 2 | 5 | ZZ | ||
58-0078-3 | 72914 | A | 5 | 2 | 5 | TX | ||
16VE345002-3 | 81755 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
51181 | KEYTRONICS INC. |
72914 | GRIMES AEROSPACE COMPANY DBA HONEYWE |
81755 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABMK | OVERALL WIDTH | 3.330 INCHES MINIMUM AND 3.390 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAU | BODY HEIGHT | 2.720 INCHES MINIMUM AND 2.780 INCHES MAXIMUM |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 4.100 POUNDS |
CRMJ | WINDING POWER RATING | 258.1 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY OUTPUT |
ADAQ | BODY LENGTH | 4.450 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY, FIXED AUTOTRANSFORMER TYPE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY INPUT |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.850 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.870 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABTB | MOUNTING HOLE DIAMETER | 0.216 INCHES MINIMUM SINGLE GROUP AND 0.226 INCHES MAXIMUM SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 29.00 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY OUTPUT |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 8.9 AMPERES NOMINAL B SINGLE COMPONENT ALL PRIMARY OUTPUT |