NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
11-00034-001 | 21562 | A | 3 | 2 | A | TX | ||
727937-2 | 21562 | A | 5 | 2 | 5 | TX |
CAGE Information
Code | Company |
---|---|
21562 | GENERAL DYNAMICS OTS AEROSPACE INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN |
ADAT | BODY WIDTH | 1.154 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 22.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ADAQ | BODY LENGTH | 1.165 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
AXGY | MOUNTING METHOD | TAB SINGLE GROUP |
CRBZ | WINDING OPERATING CURRENT | 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 50.0 WATTS SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 140.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 65.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.073 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AEHZ | MAXIMUM OPERATING TEMP | 120.0 DEG CELSIUS |
TEST | TEST DATA DOCUMENT | 16340-11-00034 DRAWING |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 1.9 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE PRIMARY |
ABKW | OVERALL HEIGHT | 1.476 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.354 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AFHM | MOUNTING TAB WIDTH | 0.012 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 4TH SECONDARY |