NIIN Output Data
NIIN:
NSN:
Item Name:
RESISTOR , THERMAL
Definition:
A THERMALLY SENSITIVE RESISTOR WHOSE PRIMARY FUNCTION IS TO EXHIBIT A CHANGE IN ELECTRICAL RESISTANCE WITH A CHANGE IN BODY TEMPERATURE. ITEM MAY BE MOUNTED IN A PROBE OR HOUSING. FOR BALLAST TUBE TYPE RESISTORS, SEE RESISTOR (1), CURRENT REGULATING. EXCLUDES TRANSMITTER (1), TEMPERATURE, ELECTRICAL RESISTANCE AND TEMPERATURE ELEMENT, RESISTANCE METEOROLOGICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RTH08BS102F | 81349 | M | 2 | 2 | E | TX | ||
MIL-T-23648/2 | 81349 | M | 4 | 1 | E | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.0/+3.0 4TH RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 100.0 KILOHMS 1ST RESISTANCE-TEMPERATURE POINT |
CQWD | ZERO POWER RESISTANCE | 1.000 KILOHMS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-T-23648/2 GOVERNMENT SPECIFICATION |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 0.0 DEG CELSIUS 3RD RESISTANCE-TEMPERATURE POINT |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 10.0 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 3.27 KILOHMS 3RD RESISTANCE-TEMPERATURE POINT |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 360.0 OHMS 4TH RESISTANCE-TEMPERATURE POINT |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
STYL | STYLE DESIGNATOR | SPHERICAL |
ADAR | BODY OUTSIDE DIAMETER | 1.460 INCHES MINIMUM AND 1.580 INCHES MAXIMUM |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 67.5 OHMS 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -15.0 DEG CELSIUS 2ND RESISTANCE-TEMPERATURE POINT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AEBT | TERMINAL DIAMETER | 0.022 INCHES MINIMUM AND 0.028 INCHES MAXIMUM |
AEHX | MAXIMUM POWER DISSIPATION RATING | 1.00 WATTS |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 25.0 DEG CELSIUS |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0/+5.0 2ND RESISTANCE-TEMPERATURE POINT |
AKNA | INCLOSURE TYPE | ENCAPSULATED |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 7.38 KILOHMS 2ND RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 100.0 DEG CELSIUS 6TH RESISTANCE-TEMPERATURE POINT |
ABDN | TERMINAL SURFACE TREATMENT | SOLDER |
CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -1.0/+1.0 |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -5.0/+5.0 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -7.0/+7.0 6TH RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 50.0 DEG CELSIUS 4TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 1ST RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | -55.0 DEG CELSIUS 1ST RESISTANCE-TEMPERATURE POINT |
ADAT | BODY WIDTH | 0.360 INCHES MAXIMUM |
AEJA | THERMAL TIME CONSTANT IN SECONDS | 250.0 |
AGAV | END ITEM IDENTIFICATION | AN/TYQ-23(V)1 |
TEST | TEST DATA DOCUMENT | 81349-MIL-T-23648 SPECIFICATION |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 125.0 DEG CELSIUS 7TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -10.0/+10.0 7TH RESISTANCE-TEMPERATURE POINT |
AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | 10.00 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 148.0 OHMS 5TH RESISTANCE-TEMPERATURE POINT |
AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -3.0/+3.0 3RD RESISTANCE-TEMPERATURE POINT |
AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | 75.0 DEG CELSIUS 5TH RESISTANCE-TEMPERATURE POINT |
CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | 34.0 OHMS 7TH RESISTANCE-TEMPERATURE POINT |