NIIN Output Data
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
726908-2 | 21562 | A | 5 | 2 | 5 | TX | ||
11-00069-002 | 21562 | A | 3 | 2 | A | TX |
CAGE Information
Code | Company |
---|---|
21562 | GENERAL DYNAMICS OTS AEROSPACE INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
TEST | TEST DATA DOCUMENT | 16340-11-00069 DRAWING |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
CRBZ | WINDING OPERATING CURRENT | 2.8 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 328.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
ACZB | FREQUENCY RATING | 28.5 KILOHERTZ NOMINAL SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 134.0 DEG CELSIUS |
FEAT | SPECIAL FEATURES | FOUR PRIMARY WINDINGS AND TWO SECONDARY WINDINGS |
CRMJ | WINDING POWER RATING | 95.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
ADAT | BODY WIDTH | 0.594 INCHES MAXIMUM |
CRMJ | WINDING POWER RATING | 339.3 VOLTS-AMPERES SINGLE COMPONENT ALL PRIMARY |
ABTB | MOUNTING HOLE DIAMETER | 0.100 INCHES MINIMUM SINGLE GROUP AND 0.140 INCHES MAXIMUM SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 4 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CWJS | WINDING OPERATING VOLTAGE | 11.31 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL PRIMARY |
CRBZ | WINDING OPERATING CURRENT | 5.8 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 30.0 AMPERES NOMINAL B SINGLE COMPONENT ALL PRIMARY |
ADAU | BODY HEIGHT | 1.280 INCHES MAXIMUM |
CWJS | WINDING OPERATING VOLTAGE | 56.56 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ADAQ | BODY LENGTH | 1.200 INCHES MAXIMUM |
CBBL | FEATURES PROVIDED | COLOR CODED TERMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE SINGLE GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 11 PIN AND 2 WIRE LEAD |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 33.94 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 2ND SECONDARY |