Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC

Definition:

A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
MIL-PRF-39016/19 81349 M 4 1 4 ZZ
M39016/19-041P 81349 M 2 2 E TX
MIL-R-39016/19 81349 M 5 9 E TX

CAGE Information

Code Company
81349 MILITARY SPECIFICATIONS PROMULGATED

Federal Supply Class

Title

RELAYS AND SOLENOIDS

Inclusions:

INCLUDES ELECTROMAGNETIC ACTUATORS.

Exclusions:

EXCLUDES CONTRACTORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TEST TEST DATA DOCUMENT 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL
AKDX WINDING QUANTITY 1
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-39016/19 GOVERNMENT SPECIFICATION
ABMK OVERALL WIDTH 0.370 INCHES MAXIMUM
AXHR MOUNTING FACILITY TYPE AND QUANTITY 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
ABKW OVERALL HEIGHT 0.300 INCHES MAXIMUM
CRXH TIME DELAY 0.002 SECONDS MAXIMUM FIXED OPERATE TIME
AFJN FRAGILITY FACTOR MODERATELY RUGGED
APCN COIL QUANTITY 1
ABHP OVERALL LENGTH 0.405 INCHES MAXIMUM
CBBL FEATURES PROVIDED COIL VOLTAGE SUPPRESSION AND POLARIZED
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 18.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
APNA WINDING DC RESISTANCE RATING 880.0 OHMS NOMINAL SINGLE WINDING
APNQ ARC QUENCHING METHOD AIR
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
ADZC ENVIRONMENTAL PROTECTION HERMETIC
TTQY TERMINAL TYPE AND QUANTITY 8 PIN ALL FUNCTIONS
APNP DUTY TYPE CONTINUOUS
AGAV END ITEM IDENTIFICATION AN/TYQ-23(V)1
FEAT SPECIAL FEATURES FAILURE RATE: 0.1 PERCENT PER 10,000 OPERATIONS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 200.0 MILLIAMPERES DC INDUCTIVE LOAD
CBME CUBIC MEASURE 0.045 CUBIC INCHES
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 MILLIAMPERES DC LAMP LOAD
CRTL CRITICALITY CODE JUSTIFICATION FEAT
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD
CRXH TIME DELAY 0.004 SECONDS MAXIMUM FIXED RELEASE TIME

Similar Parts

M39016/19-041P , M3901619041P , 5945-01-329-7858 , 5945013297858 , 013297858 , MIL-PRF-39016/19 , M39016/19-041P , MIL-R-39016/19 ,