NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
M6106/11-002 | 81349 | M | 2 | 2 | E | TX | ||
MIL-PRF-6106/11 | 81349 | M | 4 | 1 | 4 | ZZ | ||
MIL-R-6106/11 | 81349 | M | 5 | 9 | E | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC RESISTIVE LOAD AND 60.0 AMPERES DC RESISTIVE LOAD |
CBME | CUBIC MEASURE | 16.831 CUBIC INCHES |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 20.0 AMPERES AC LAMP LOAD AND 20.0 AMPERES DC LAMP LOAD |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
AKDX | WINDING QUANTITY | 2 |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 29.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
CRXH | TIME DELAY | 0.025 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
ABMK | OVERALL WIDTH | 2.313 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.365 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.5 PROBE AC INDUCTIVE LOAD AND 1.5 PROBE DC INDUCTIVE LOAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-6106/11 GOVERNMENT SPECIFICATION |
ABKW | OVERALL HEIGHT | 3.032 INCHES MAXIMUM |
APCN | COIL QUANTITY | 1 |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 60.0 AMPERES AC INDUCTIVE LOAD AND 60.0 AMPERES DC INDUCTIVE LOAD |
CBBL | FEATURES PROVIDED | LATCHING CONTACTS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.148 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APNQ | ARC QUENCHING METHOD | AIR |
CSQC | AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 500.0 DUAL 16 STAGE AC LAMP LOAD AND 500.0 DUAL 16 STAGE DC LAMP LOAD |
ABHP | OVERALL LENGTH | 2.400 INCHES MAXIMUM |
APNP | DUTY TYPE | CONTINUOUS |
AGAV | END ITEM IDENTIFICATION | E-3 FACS RAOV |
CWGM | AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 3.0 PROBE AC RESISTIVE LOAD AND 3.0 PROBE DC RESISTIVE LOAD |
CSKP | NONPILE-UP AUXILIARY CONTACT ARRANGEMENT | 1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 40.0 AMPERES AC MOTOR LOAD AND 40.0 AMPERES DC MOTOR LOAD |
TTQY | TERMINAL TYPE AND QUANTITY | 11 SOLDER STUD ALL FUNCTIONS |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |