NIIN Output Data
NIIN:
NSN:
Item Name:
BALLAST , LAMP
Definition:
AN ITEM SPECIFICALLY DESIGNED FOR USE WITH FLUORESCENT OR MERCURY VAPOR LAMPS AND STARTERS TO PROVIDE A HIGH STARTING VOLTAGE FOR STRIKING THE ARC AND TO STABILIZE THE OPERATING IMPEDANCE OF THE CIRCUIT IN ORDER TO MAINTAIN THE OPERATING CURRENT AT A STEADY VALUE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
11932 | 98775 | A | 5 | 2 | E | CX | ||
H-1B13-TP | 98775 | A | 3 | 2 | E | CX |
CAGE Information
Code | Company |
---|---|
98775 | PHILIPS LIGHTING ELECTRONICS COMPANY |
Federal Supply Class
Title
BALLASTS, LAMPHOLDERS, AND START
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADJH | MOUNTING METHOD | HOLES |
ABTJ | MOUNTING HOLE QUANTITY | 4 |
ARQF | STARTING CHARACTERISTIC | PREHEAT |
AMSE | VOLTAGE RATING | 120.0 VOLTS NOMINAL |
ARGL | POWER FACTOR CHARACTERISTIC | HIGH |
ABHP | OVERALL LENGTH | 4.250 INCHES NOMINAL |
ABTB | MOUNTING HOLE DIAMETER | ANY ACCEPTABLE |
AMPS | CURRENT RATING IN AMPS | 0.150 |
CWAD | LAMP TYPE ACCOMMODATED | ENERGY EFFICIENT |
ARQG | STARTER | NOT REQUIRED |
ADHW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG WIDTH | ANY ACCEPTABLE |
ACZB | FREQUENCY RATING | 60.0 HERTZ NOMINAL |
ABKW | OVERALL HEIGHT | 1.438 INCHES NOMINAL |
AEUH | LAMP ACCOMMODATION QUANTITY | 1 |
ADHV | CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG LENGTH | 3.562 INCHES |
AARB | TERMINAL TYPE | WIRE LEAD |
ACDC | CURRENT TYPE | AC |
AEWS | LAMP WATTAGE RATING IN WATTS | 13.0 |
ARQH | TERMINAL LOCATION AND QUANTITY | 3 ONE END |
AARA | TERMINAL QUANTITY | 3 |
FEAT | SPECIAL FEATURES | ENCAPSULATED; USED W/SHORT COMPACT FLUORESCENT LAMPS; POWER FACTOR CORRECTED |
ABMK | OVERALL WIDTH | 2.000 INCHES NOMINAL |