NIIN Output Data
Definition:
A DEVICE CAPABLE OF PRODUCING HEAT FROM GAS, LIQUID FUEL, OR AN ELECTRICAL HEATING ELEMENT DESIGNED FOR PERMANENT INSTALLATION IN SHEET METAL DUCTS OF A FORCED AIR CIRCULATING SYSTEM. IT CONSISTS OF (1) A FINNED, STEEL BURNER TUBE, A COMBUSTION AIR BLOWER, A CONTROL PANEL, AND A CONSTANT LEVEL FUEL SUPPLY SYSTEM OR (2) A DEVICE HAVING A HEATING ELEMENT WHICH WHEN CONNECTED TO AN ELECTRICAL SOURCE, DIRECTLY IMPARTS HEAT. IT MAY BE PROVIDED WITH A FLANGED OUTER CASING TO FACILITATE MOUNTING IN PLANNED OR EXISTING DUCT WORK. CIRCULATION OF THE HEATED AIR IS ACHIEVED BY USE OF A BLOWER OR FAN NOT INTEGRAL WITH THE HEATING UNIT.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
D200K0 B07246 | 74924 | A | D | 9 | A | AX | ||
TFZ-0.99-8X8-120/1/1/120 | 74924 | A | 5 | 2 | E | AX | ||
D200K0 B07246 ITEM 01-45-2 | 74924 | A | 3 | 2 | E | AX |
CAGE Information
Code | Company |
---|---|
74924 | INDUSTRIAL ENGINEERING AND EQUIPMENT |
Federal Supply Class
Title
SPACE AND WATER HEATING EQUIPMEN
Inclusions:
INCLUDES BOILERS, 15 POUNDS WSP AND UNDER (FOR BOILERS OVER 15 POUNDS WSP, SEE FSC 4410); DOMESTIC WATER STORAGE TANKS THROUGH 100 GALLON CAPACITY; FIREPLACE HEATERS; FURNACES; SPACE HEATERS; HEATING RADIATORS; IMMERSION HEATERS; WATER HEATERS, THROUGH 100 GALLON RECOVERY CAPACITY (FOR HEATERS OVER 100 GALLONS RECOVERY CAPACITY, SEE FSC 4410).
Exclusions:
EXCLUDES VEHICLE HEATERS; (FSC 2540); AIRCRAFT HEATERS (FSC 1660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABAW | HEAT OUTLET QUANTITY | 1 |
ABAZ | HEAT DIRECTING DEVICE | ADJUSTABLE LOUVER |
FREQ | FREQUENCY IN HERTZ | 60.0 |
ABAY | HEAT DISCHARGE OUTLET TYPE | ADJUSTABLE |
ALYC | OPERATING CONTROL TYPE | THERMOSTATIC |
AAXX | MOUNTING TYPE | ANY ACCEPTABLE |
ELEC | VOLTAGE IN VOLTS | 120.0 |
ABAX | HEAT DELIVERY DIRECTION | HORIZONTAL |
CQXD | HEAT DELIVERY RATE | 3377.88 BRITISH THERMAL UNIT |
BDXJ | HEATING ELEMENT TYPE | ELECTRIC NONIMMERSION |
ABGL | WIDTH | 8.000 INCHES NOMINAL |
ABAM | HEAT MEDIUM TYPE | AIR |
HGTH | HEIGHT | 8.000 INCHES NOMINAL |
AMPS | CURRENT RATING IN AMPS | 8.25 |
ACDC | CURRENT TYPE | AC |
FAAZ | PHASE | SINGLE |