NIIN Output Data
Definition:
TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
LE572-0053-5122 | 43999 | A | 7 | 2 | A | ZZ | ||
B1-0112 | 12515 | A | 3 | 2 | 5 | KZ | ||
12731/20079KK2 | 92607 | A | 3 | 2 | 5 | KZ | ||
LB-B1-5122 | 28427 | A | 3 | 2 | 5 | KZ | ||
30-90497/12 | 05973 | F | 3 | 2 | 5 | KZ |
CAGE Information
Code | Company |
---|---|
05973 | CHAMPLAIN CABLE CORP SUB OF HUBER AN |
43999 | BOEING COMPANY THE DBA BOEING DIV DE |
12515 | NEXANS USA INC. DBA NEXANS BERK TEK |
92607 | TENSOLITE LLC DBA CARLISLE INTERCONN |
28427 | BARCEL/CDT |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.247 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXDC | ROUND CONDUCTOR SIZE | 12 AWG ALL CONDUCTORS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B355 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 28 ALL CONDUCTORS |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 37 ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 2 SINGLES |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
ZZZW | DEPARTURE FROM CITED DOCUMENT | AS MODIFIED BY OUTER JACKET COLOR AND COLOR BANDS ON BASIC WIRE |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
SFTT | SURFACE TREATMENT | NICKEL CORE CONDUCTOR ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | A DOUBLE YELLOW BAND SHALL BE APPLIED EVERY 2 3/4 INCHES ON BASIC WIREA SINGLE BLACK BAND SHALL BE APPLIED EVERY 2 3/4 INCHES ON BASIC WIRE |
ASGF | TRACER COLOR | BLUE SINGLE TRACER SECOND CONDUCTOR |