NIIN Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
81644 | 81774 | A | 3 | 2 | E | KZ | ||
13229E0886-1 | 97403 | A | 7 | 2 | A | KZ |
CAGE Information
Code | Company |
---|---|
81774 | GENERAL CABLE CORPORATION DBA GENERA |
97403 | CECOM LR CENTER |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
FEAT | SPECIAL FEATURES | OUTER JACKET COMPOUND IS SUPER VU-TRON II |
HUES | COLOR | BLACK 1ST POSITION PRIMARY INSULATION FIRST CONDUCTOR |
MATT | MATERIAL | RUBBER SYNTHETIC 2ND POSITION JACKET CABLE |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 4 SINGLES |
ABJH | TEMP RATING | -40.0 DEG CELSIUS AND 90.0 DEG CELSIUS |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B172 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
HUES | COLOR | RED 1ST POSITION PRIMARY INSULATION THIRD CONDUCTOR |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
MATT | MATERIAL | RUBBER ETHYLENE-PROPYLENE-DIENE CLASS EPDM 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 1.270 INCHES NOMINAL |
HUES | COLOR | GREEN 1ST POSITION PRIMARY INSULATION FOURTH CONDUCTOR |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
HUES | COLOR | WHITE 1ST POSITION PRIMARY INSULATION SECOND CONDUCTOR |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 259 ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 4 |
HUES | COLOR | BLACK 2ND POSITION JACKET CABLE |
CXDC | ROUND CONDUCTOR SIZE | 4 AWG ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 27 ALL CONDUCTORS |