NIIN Output Data
Definition:
TWO OR MORE INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING, COVERING, SHIELD, OR OUTER CONDUCTOR. THE RATED WORKING VOLTAGE OF THE ITEM MUST BE 300 VOLTS OR MORE, OR IN LIEU OF THIS THE TEST VOLTAGE MUST BE 1,000 VOLTS OR MORE; AND THE SIZE OF EACH INDIVIDUAL CONDUCTOR MUST BE NUMBER 18 AMERICAN WIRE GAGE (0.75 SQUARE MILLIMETERS) OR LARGER. FOR CABLES WITH UNINSULATED NEUTRAL CONDUCTOR USE THE HIGHTEST RATED VOLTAGE. REFERS TO BULK QUANTITIES ONLY, FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, POWER, ELECTRICAL. FOR LOW VOLTAGE AIRCRAFT AND AUTOMOTIVE CABLE, SEE CABLE, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
V3442 | 07909 | A | C | 1 | 5 | ZZ | 9X | |
V3442 | 82879 | A | 3 | 9 | E | KZ |
CAGE Information
Code | Company |
---|---|
07909 | SOUTHWIRE COMPANY DOUGLAS PLANT |
82879 | YORK TECHNICAL INSTITUTE LLC DBA YTI |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CXDC | ROUND CONDUCTOR SIZE | 00 AWG ALL CONDUCTORS |
MATT | MATERIAL | RUBBER CHLOROSULFONATED POLYETHYLENE CLASS CSM 3RD POSITION JACKET CABLE |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 23 ALL CONDUCTORS |
ABJH | TEMP RATING | 90.0 DEG CELSIUS |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
AWTB | ACCESSORY WIRE TYPE AND QUANTITY | 3 GROUND |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 1.950 INCHES NOMINAL |
AMQN | CONDUCTOR QUANTITY | 3 |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
MATT | MATERIAL | RUBBER ETHYLENE-PROPYLENE CLASS EPM 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | TYPE G OR GC |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 259 ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 3 SINGLES |
MATT | MATERIAL | FIBER SYNTHETIC 2ND POSITION BRAID, NON-METALLIC CABLE |