Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
VALVE , LINEAR , DIRECTIONAL CONTROL

Definition:

A MANUALLY OR POWER OPERATED VALVE HAVING THREE OR MORE PORTS. THE DIRECTION OF THE FLOW THROUGH THE VARIOUS PORTS IS CONTROLLED BY EITHER ONE OR MORE RECIPROCATING SLIDE(S) OR SPOOL(S) WITH RECESS AREAS WHICH MATE WITH PORTS IN AN INTEGRAL OR REPLACEABLE PORTED SLEEVE, OR ONE OR MORE POPPET(S). IT IS DESIGNED TO CHANGE THE DIRECTION OF FLUID FLOW FROM ONE VALVE PORT TO ANOTHER. AN OFF (NO FLOW) POSITION IS NOT A FLOW PATTERN. THE VALVE IS DESIGNED TO ACTUATE VARIOUS COMPONENTS OF A FLUID SYSTEM. A POWER OPERATED VALVE MAY HAVE A MANUAL OVERRIDE. FOR ITEMS WHICH STOP, START, OR CHANGE THE FLOW OF FLUID, SEE: VALVE, SOLENOID. EXCLUDES VALVE, PLUG. SEE ALSO SERVOVALVE, HYDRAULIC; BODY SECTION, WORKING, LINEAR DIRECTIONAL CONTROL VALVE; AND VALVE ASSEMBLY.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
VGG-4522-XN-A120 97902 A 3 2 5 ZZ
VGG-4522-CLL80-TR50-XXEN-120V60 97902 A 5 9 4 9Z

CAGE Information

Code Company
97902 VERSA PRODUCTS CO INC

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CQJX NOMINAL THREAD SIZE 0.250 INCHES
AWLS CONNECTION TYPE THREADED INTERNAL TUBE
THSD THREAD SERIES DESIGNATOR NPT
CRWH MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED 200.0 DEG FAHRENHEIT FUEL/OIL, HYDROCARBON
CQRG BODY MATERIAL STEEL CORROSION RESISTING
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 120.0 AC
AQLR VALVE OPERATION METHOD MANUAL
AMPS CURRENT RATING IN AMPS 0.25
CYGY FLOW PATTERN QUANTITY 4
CQCJ MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED 200.0 POUNDS PER SQUARE INCH FUEL/OIL, HYDROCARBON

Similar Parts

VGG-4522-CLL80-TR50-XXEN-120V60 , VGG4522CLL80TR50XXEN120V60 , 4810-01-364-8051 , 4810013648051 , 013648051 , VGG-4522-XN-A120 , VGG-4522-CLL80-TR50-XXEN-120V60 ,