NIIN Output Data
NIIN:
NSN:
Item Name:
RESISTOR , FIXED , WIRE WOUND , NONIND
Definition:
INC 37404 REINSTATED ON 010303~A RESISTOR WHOSE OHMIC VALUE CANNOT BE ADJUSTED OR VARIED. THE RESISTANCE ELEMENT CONSISTS OF HIGH RESISTANCE WIRE (OR RIBBON) EITHER WOUND ON AN INSULATED FORM OR CONSTRUCTED SO AS TO BE SELF-SUPPORTING. THE ITEMS MUST HAVE INHERENT CHARACTERISTICS OF INDUCING LITTLE OR NO SELF-INDUCTANCE. OPPOSITION TO CURRENT FLOW IS AN INHERENT PROPERTY OF THE RESISTANCE WIRE AND IS MANIFESTED BY THE HEAT DISSIPATION IN THE RESISTOR. EXCLUDES SUPPRESSOR, IGNITION INTERFERENCE. SEE ALSO RESISTOR (1), FIXED, WIRE WOUND, INDUCTIVE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
RWR80N1R50FS | 81349 | M | 2 | 2 | E | TX | ||
MIL-R-39007/8 | 81349 | M | 4 | 1 | E | TX |
CAGE Information
Code | Company |
---|---|
81349 | MILITARY SPECIFICATIONS PROMULGATED |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -50.0/+50.0 |
ABPM | BODY DIAMETER | 0.063 INCHES MINIMUM AND 0.125 INCHES MAXIMUM |
AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.001 |
TEST | TEST DATA DOCUMENT | 81349-MIL-R-39007 SPECIFICATION |
AARG | RELIABILITY INDICATOR | ESTABLISHED |
AAQZ | INCLOSURE METHOD | ENCAPSULATED |
AEFB | POWER DISSIPATION RATING IN WATTS | 2.000 FREE AIR |
AAPP | ELECTRICAL RESISTANCE | 1.500 OHMS |
ABJT | TERMINAL LENGTH | 1.500 INCHES MINIMUM |
AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 25.0 |
STYL | STYLE DESIGNATOR | AXIAL TERMINAL EACH END |
AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -55.0/+275.0 |
ADAQ | BODY LENGTH | 0.375 INCHES MINIMUM AND 0.437 INCHES MAXIMUM |
AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000/+1.000 |
AARB | TERMINAL TYPE | WIRE LEAD |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-R-39007/8 GOVERNMENT SPECIFICATION |
AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 275.0 |