TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS (SOLID OR STRANDED) CONTAINED IN A COMMON COVERING, OR TWO OR MORE INDIVIDUALLY INSULATED CONDUCTORS TWISTED OR MOLDED TOGETHER WITHOUT A COMMON COVERING, OR ONE INSULATED CONDUCTOR WITH A METALLIC COVERING OR SHIELD; EACH HAVING CHARACTERISTICS NOT COMPLETELY CONFORMING TO CABLE, TELEPHONE; CABLE, POWER, ELECTRICAL; CABLE, RADIO FREQUENCY OR CORD, ELECTRICAL. INCLUDES ITEMS HAVING THE COMBINED CHARACTERISTICS OF TWO OR MORE OF THE AFOREMENTIONED NAMES. REFERS TO BULK QUANTITIES ONLY; FOR ITEMS OF DEFINITE LENGTH WITH PROCESSED ENDS OR TERMINATED IN FITTINGS, SEE CABLE ASSEMBLY, SPECIAL PURPOSE, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
T26IP19N5/STP | 60990 | A | 3 | 2 | 5 | ZZ | ||
3271243-1 | 5F262 | A | 5 | 2 | 5 | ZZ | ||
3271243-1 | 10001 | A | 5 | 2 | A | ZZ | ||
PE5R-1938-IF-10TW | 19449 | A | 5 | 9 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
10001 | NAVAIR AND NAVSEA MANAGED ORIGINAL D |
60990 | GSI CORPORATION |
5F262 | GENERAL WIRE PRODUCTS INC. |
19449 | BERK-TEK A NEXANS COMPANY DBA BERK-T |
Federal Supply Class
Title
WIRE AND CABLE, ELECTRICAL
Inclusions:
INCLUDES INSULATED AND NONINSULATED, WIRE AND CABLE, SUCH AS, ANTENNA WIRE, COAXIAL CABLE, FUSE AND RESISTANCE WIRE, AND MAGNET WIRE.
Exclusions:
EXCLUDES RADIO FREQUENCY TRANSMISSION LINE (FSC 5985); FIBER OPTIC CABLE (FSC 6015); COMMUNICATION CABLE ASSEMBLIES (FSC 5995); DISTRIBUTION AND POWER TRANSMISSION CABLE ASSEMBLIES (FSC 6150).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE TREATMENT RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
AMQN | CONDUCTOR QUANTITY | 20 |
MDCL | MATERIAL DOCUMENT AND CLASSIFICATION | ASTM B33 ASSN STD SINGLE MATERIAL RESPONSE CORE CONDUCTOR ALL CONDUCTORS |
ADWH | CROSS-SECTIONAL WIDTH | 0.750 INCHES NOMINAL |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 38 ALL CONDUCTORS |
CXFK | VOLTAGE RATING | 600.0 MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE ALL CONDUCTORS |
MATT | MATERIAL | PLASTIC CROSS LINKED POLYETHYLENE 1ST POSITION PRIMARY INSULATION ALL CONDUCTORS |
FEAT | SPECIAL FEATURES | THE TWISTED PAIRS SHALL BE WOVEN TOGETHER IN A FLAT CONFIGURATION WITH A 2X2 TWILL WEAVE OF 840 DENIER HIGH TENACITY (HIGH DENSITY) ,WHITE OR NATURAL COLOR NOMEX FILAMENT YARN. |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 10 TWISTED PAIR |
SFTT | SURFACE TREATMENT | TIN CORE CONDUCTOR ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED ALL CONDUCTORS |
AWXS | COLOR CODING DOCUMENT | 3271243-10001 SPECIFICATION |
AAGR | CROSS-SECTIONAL SHAPE STYLE | FLAT |
BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 ALL CONDUCTORS |
CXDC | ROUND CONDUCTOR SIZE | 26 AWG ALL CONDUCTORS |
ABJH | TEMP RATING | 1.0 DEG CELSIUS AND 79.0 DEG CELSIUS |