NIIN Output Data
Definition:
A SET (BANK) OF ELECTRICAL ELEMENTS THAT ARE PASSIVE (RESISTIVE, INDUCTIVE, CAPACITIVE) OR ACTIVE (MOTORS, BATTERIES). THEY ARE USUALLY LOCATED ADJACENT TO EACH OTHER TO FORM A CONSOLIDATED SET OF ANY OF THESE ELEMENTS OR ANY COMBINATION OF THEM. A LOAD BANK IS USED TO REPLACE DISTRIBUTED OR DISPERSED LOAD ELEMENTS CONTAINED IN A POWER DISTRIBUTION SYSTEM OR ELECTRICAL NETWORK FOR THE PURPOSE OF PROVIDING A CONCENTRATED LOAD. A LOAD BANK CONTAINS ALL THE ESSENTIAL ELECTRICAL CHARACTERISTICS NECESSARY TO TERMINATE THE CIRCUIT AND FUNCTIONS IN THE SAME MANNER AS THE LOAD WHICH IT IS INTENDED TO REPLACE. THIS DESCRIPTION NECESSARILY INCLUDES A BANK OF LIGHT BULBS OR CONE HEATING ELEMENTS WHERE ENERGY CONVERSION IS PRIMARILY IN THE FORM OF HEAT ALTHOUGH VISIBLE RADIANT ENERGY IS THE NATURAL RESULT OF INCANDESCENT HEATING. LOAD BANKS ARE INTENDED TO COVER A SPECIFIC RANGE OF CHARACTERISTICS AND NORMALLY OPERATE AT DC OR AT POWER FREQUENCIES 50, 60, OR 400 HZ AC. LOAD BANKS MAY BE UNINSTRUMENTED OR COMPLETE WITH INTEGRAL INSTRUMENTION AND MAY ALSO BE FURNISHED AS SKID OR TRAILER MOUNTED. EXCLUDES TEST SET, ELECTRICAL (AS MODIFIED). SEE ALSO DUMMY LOAD, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
K575/D19710 | 01014 | A | 3 | 2 | 2 | ZZ |
CAGE Information
Code | Company |
---|---|
01014 | AVTRON AEROSPACE INC. |
Federal Supply Class
Title
MISCELLANEOUS ELECTRIC POWER AND
Inclusions:
INCLUDES APPLIANCE AND EXTENSION CORDS; ELECTRIC POWER AND DISTRIBUTION CABLE WITH ATTACHMENTS, MULTIAPPLICATION; COMMON COMPONENTS OF ELECTRICAL ROTATING EQUIPMENT, SUCH AS END BELLS AND FRAMES.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
AKVZ | ACCESSORY IDENTIFYING NUMBER | K575/D19710 PART NO. |
AKVY | ACCESSORY CONTROLLING AGENCY | AVTRON MANUFACTURING, INC |
ABRY | LENGTH | 72.000 INCHES MINIMUM AND 82.500 INCHES MAXIMUM |
ALSF | INTERNAL BATTERY ACCOMMODATION | NOT INCLUDED |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | SELF-CONTAINED |
HGTH | HEIGHT | 48.500 INCHES NOMINAL |
AEAS | MAJOR COMPONENTS | LOUVERS, FORK LIFT CHANNELS, BLOWER, SWITCHES, DIFERENTIAL PRESSURE SWITCH |
FEAT | SPECIAL FEATURES | NOMENCLATURE LOAD BANK TESTER; TEMP CONTROLLED WATER TIGHT CONTACTOR ENCLOSURE; NO COOL DOWN PERIOD; OPTIONS OPTIONAL DC DESIGNS; OPTIONAL ENCLOSURE; KW METER; VOLTMETER, AMMETER AND FREQUENCY METER; METER AND CONTROL PANELENCLOSURE; 208,230,575V BLOWERS; CONTROL TRANSFORMER |
AQXY | TEST TYPE FOR WHICH DESIGNED | STANDBY EMERGENCY POWER SOURCE |
ABGL | WIDTH | 60.000 INCHES NOMINAL |