NIIN Output Data
NIIN:
NSN:
Item Name:
CABLE ASSEMBLY , SPECIAL PURPOSE , E
Definition:
A DEFINITE CONTINUOUS LENGTH OF CABLE, SPECIAL PURPOSE, ELECTRICAL, HAVING ONE OR MORE ENDS PROCESSED OR TERMINATED IN FITTINGS WHICH PROVIDE FOR CONNECTION TO OTHER ITEMS. EXCLUDES ITEMS HAVING BRANCHES OR FORKS. EXCLUDES LEAD, TEST AND CABLE AND CONDUIT ASSEMBLY, ELECTRICAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
09-2734056-301 | 67032 | A | 3 | 2 | 2 | ZZ | ||
09-2734056-34 | 67032 | A | 5 | 2 | 5 | ZZ | ||
09-2734056-35 | 67032 | A | 5 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
67032 | GENERAL DYNAMICS C4 SYSTEMS INC. |
Federal Supply Class
Title
CABLE, CORD, AND WIRE ASSEMBLIES
Inclusions:
Exclusions:
EXCLUDES CABLE ASSEMBLIES, FIBER OPTIC.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AMQN | CONDUCTOR QUANTITY | 2 |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
MATT | MATERIAL | COPPER 2ND POSITION SHIELD BRAID, METALLIC SECOND CONDUCTOR |
MATT | MATERIAL | COPPER CORE CONDUCTOR FIRST CONDUCTOR |
MATT | MATERIAL | PLASTIC POLYETHYLENE 1ST POSITION SECONDARY INSULATION CABLE |
CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | 1 TRIAXIAL |
MATT | MATERIAL | PLASTIC POLYVINYL CHLORIDE 5TH POSITION COVER CABLE |
MATT | MATERIAL | PLASTIC FLUORINATED ETHYLENE PROPYLENE 3RD POSITION SECONDARY INSULATION CABLE |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | J72S-9 1ST END ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | STRANDED 1ST CONDUCTOR |
AKRZ | TERMINATION TYPE | CONNECTOR RECEPTACLE 1ST END ALL CONDUCTORS |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY ELECTRICAL-SIGNAL |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 29 1ST CONDUCTOR |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 36 2ND CONDUCTOR |
CXDG | STRAND AWG SIZE PER CONDUCTOR | 36 3RD CONDUCTOR |
MATT | MATERIAL | COPPER 4TH POSITION SHIELD BRAID, METALLIC THIRD CONDUCTOR |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 14949 1ST END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | PL-75-2 2ND END ALL CONDUCTORS |
AKRZ | TERMINATION TYPE | CONNECTOR PLUG 2ND END ALL CONDUCTORS |
STYL | STYLE DESIGNATOR | DUAL JACK |
AWTB | ACCESSORY WIRE TYPE AND QUANTITY | 1 GROUND |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 14949 2ND END ALL CONDUCTORS |
CXCW | CONDUCTOR FORM | BRAID, TUBULAR 2ND CONDUCTOR |
CXCW | CONDUCTOR FORM | BRAID, TUBULAR 3RD CONDUCTOR |
ABJH | TEMP RATING | -55.0 DEG CELSIUS AND 200.0 DEG CELSIUS |
AGAV | END ITEM IDENTIFICATION | AN/TTC-39E(V)1 |
ALBY | USAGE DESIGN | SWITCHBOARD WIRE |
CXDC | ROUND CONDUCTOR SIZE | 20.00 AWG 1ST CONDUCTOR |
ADVL | CROSS SECTION OUTSIDE DIAMETER | 0.104 INCHES MINIMUM AND 0.128 INCHES MAXIMUM |
CXGW | INDIVIDUAL CONDUCTOR LENGTH | 52.000 INCHES MINIMUM BOTH ENDS ALL CONDUCTORS AND 54.000 INCHES MAXIMUM BOTH ENDS ALL CONDUCTORS |