NIIN Output Data
NIIN:
NSN:
Item Name:
HOSE ASSEMBLY , NONMETALLIC
Definition:
A LENGTH OF NONMETALLIC HOSE WITH FITTINGS ON ONE OR BOTH ENDS. FOR ITEMS WITHOUT FITTINGS, SEE HOSE, NONMETALLIC. EXCLUDES HOSE ASSEMBLY, AIR DUCT; AND HOSE ASSEMBLY, AIR DUCT, AIR BREATHING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
05008-20 | 64903 | A | 3 | 2 | E | ZZ | ||
9H0559 | 45152 | A | 3 | 2 | E | ZZ | ||
05008-XX | 64903 | A | D | 9 | A | ZZ |
CAGE Information
Code | Company |
---|---|
45152 | OSHKOSH CORPORATION |
64903 | FIRE COMBAT INC. |
Federal Supply Class
Title
HOSE AND FLEXIBLE TUBING
Inclusions:
INCLUDES AIR DUCT, METALLIC, NONMETALLIC, AND TEXTILE FIBER HOSES AND THEIR ASSEMBLIES; FLEXIBLE TUBING AND THEIR ASSEMBLIES.
Exclusions:
EXCLUDES CONDUIT AND THEIR ASSEMBLIES (FSC 5975); LABORATORY TUBES (FSC 6640); MEDICAL AND SURGICAL TUBES (FSC 6515); RIGID TUBING AND THEIR ASSEMBLIES (FSC 4710).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRWL | INSIDE SURFACE CONDITION | SMOOTH |
AAGR | CROSS-SECTIONAL SHAPE STYLE | ROUND |
CQGM | MAXIMUM OPERATING PRESSURE | 350.0 POUNDS PER SQUARE INCH |
CQBD | BURST TEST PRESSURE | 1400.0 POUNDS PER SQUARE INCH |
ABJH | TEMP RATING | -40.0 DEG FAHRENHEIT SINGLE RESPONSE AND 200.0 DEG FAHRENHEIT SINGLE RESPONSE |
CQJX | NOMINAL THREAD SIZE | 0.500 INCHES 1ST END |
THSD | THREAD SERIES DESIGNATOR | NPT 1ST END |
ACKH | MINIMUM INSIDE BENDING RADIUS | 5.000 INCHES |
AGAV | END ITEM IDENTIFICATION | FIRETRUCK, P-19 |
CQGH | FIRST END FITTING/COMPONENT AND MATERIAL | COMPLETE FITTING BRASS |
ABKV | OUTSIDE DIAMETER | 0.938 INCHES MAXIMUM |
CQCS | LAYER COMPOSITION AND LOCATION | OUTER LAYER MOLDED RUBBER, SYNTHETIC ERR-100 |
CQBG | FIRST END SWIVEL ACTION CAPABILITY | NOT INCLUDED |
AAJF | THREAD DIRECTION | RIGHT-HAND 1ST END |
CBBL | FEATURES PROVIDED | PERFORATED OUTER COVER |
AWLS | CONNECTION TYPE | THREADED EXTERNAL PIPE 1ST END |
CRDW | HYDROSTATIC TEST PRESSURE | 700.0 POUNDS PER SQUARE INCH |
CRXX | MEASURING METHOD AND LENGTH | 20.000 INCHES NOMINAL OVERALL |
CQCS | LAYER COMPOSITION AND LOCATION | 1ST LAYER BRAIDED TEXTILE YARN ERR-100 |
CQBB | SECOND END RELATIONSHIP WITH FIRST END | IDENTICAL |
AKUU | END CONNECTION DESIGN | STRAIGHT 1ST END |
MEDA | MEDIA FOR WHICH DESIGNED | FUEL/OIL, HYDROCARBON SINGLE RESPONSE AND HYDRAULIC FLUID, WATER BASE SINGLE RESPONSE |
ADJM | INNER CONVEYING TUBE MATERIAL | RUBBER, SYNTHETIC |
AARX | INSIDE DIAMETER | 0.625 INCHES NOMINAL |
ADLF | HOSE OR TUBING SPEC/STD DATA | SAE J517, 100R6-81343 STANDARD (INCLUDES INDUSTRY OR ASSOCIATION STANDARDS, INDIVIDUAL MANUFACTUREER STANDARDS, ETC.). |
AHNC | CONNECTION STYLE | PLAIN 1ST END |