NIIN Output Data
Definition:
A FLUID LINE FITTING HAVING AN EXTERNAL QUICK DISCONNECT FEATURE, DESIGNED TO BE INSERTED INTO A FITTING WITH AN INTERNAL QUICK DISCONNECT FEATURE TO BLOCK THE FLOW OF FLUID. EXCLUDES PLUG, PROTECTIVE, DUST AND MOISTURE SEAL.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
G1-29-9174-001 | 55827 | A | 5 | 2 | E | ZZ | ||
G1-29-9174 | 55827 | A | 7 | 2 | A | ZZ | ||
VP-Q4V-SSP | 97111 | A | 3 | 2 | E | ZZ |
CAGE Information
Code | Company |
---|---|
55827 | DME CORPORATION |
97111 | PARKER-HANNIFIN CORPORATION DBA QUIC |
Federal Supply Class
Title
HOSE, PIPE, TUBE, LUBRICATION, A
Inclusions:
INCLUDES ADAPTERS; BENDS; CAPS; CLAMPS; CONNECTORS; COUPLINGS; CROSSES; ELBOWS; EXPANSION JOINTS; FERRULES; FLANGES; LATERALS; LUBRICATION FITTINGS; MANIFOLDS; NIPPLES; NOZZLES; OUTLETS; PLUGS; REDUCERS; SWING AND SWIVEL JOINTS; TEES; TRAPS; UNIONS; WYES.
Exclusions:
EXCLUDES AIR CONDITIONING-HEATING FITTINGS (FSC 4520); BITUMINIZED FIBER AND CONCRETE FITTINGS (FSC 5630); CONDUIT BOXES AND FITTINGS (FSC 5975); DOWNSPOUT FITTINGS (FSC 5670); MEDICAL AND SURGICAL FITTINGS (FSC 6515); LABORATORY FITTINGS (FSC 6640); POST CAPS AND RAIL ENDS (FSC 5660); MACHINE THREAD BUSHINGS AND PLUGS (FSC 5365).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
TMQY | FURNISHED ITEMS AND QUANTITY | 1 CAP AND 1 CHAIN |
AEHZ | MAXIMUM OPERATING TEMP | 55.0 DEG CELSIUS |
MATT | MATERIAL | STEEL CORROSION RESISTING BODY |
AGAV | END ITEM IDENTIFICATION | ACFT,AC-130,AC-130H,MC-130H,EC-130 |
CQGM | MAXIMUM OPERATING PRESSURE | 250.0 POUNDS PER SQUARE INCH |
ADLN | QUICK DISCONNECT METHOD | PUSH-PULL |
SFTT | SURFACE TREATMENT | PASSIVATE BODY |
ABHP | OVERALL LENGTH | 1.370 INCHES NOMINAL |