NIIN Output Data
NIIN:
NSN:
Item Name:
THERMOMETER , SELF-INDICATING , DIGI
Definition:
A DEVICE WHOSE MEASURABLE PHYSICAL PROPERTIES CHANGE WITH VARIATION IN TEMPERATURE. THE TEMPERATURE READING APPEARS IN EITHER DEGREES CELSIUS OR DEGREES FAHRENHEIT ON A SELF-INDICATING DIGITAL DISPLAY. THE DEVICE OPERATES IN CONJUNCTION WITH THERMOCOUPLES AND IS POWERED BY AN ELECTRIC CURRENT. EXCLUDES INDICATOR, TEMPERATURE, THERMOCOUPLE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
KPTRF-50 | 0JEA8 | A | 5 | 9 | 5 | ZZ | ||
KPTRF-80 | 0JEA8 | A | 3 | 2 | 5 | ZZ |
CAGE Information
Code | Company |
---|---|
0JEA8 | KAYMONT CONSOLIDATED INDUSTRIES INC |
Federal Supply Class
Title
PRESSURE, TEMPERATURE, AND HUMID
Inclusions:
INCLUDES THERMOMETERS, INCLUDING ENGINE THERMOMETERS; PRESSURE GAGES; THERMOCOUPLE LEADS; RESISTANCE BULBS.
Exclusions:
EXCLUDES CLINICAL THEROMETERS; (FSC 6515); THERMOSTATIC AND DIFFERENTIAL PRESSURE SWITCHES (FSC 5930); AND METEOROLOGICAL INSTRUMENTS (FSC 6660).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BHMW | MEASUREMENT RANGE | -18.0/+870.0 DEG CELSIUS |
BFQP | DISPLAY DIGIT QUANTITY | 4 |
STYL | STYLE DESIGNATOR | PORTABLE, SELECTOR SWITCH |
BKCN | SCALE ACCURACY RATING | 1.0 DEG CELCIUS FULL RANGE OF SCALE |
FEAT | SPECIAL FEATURES | LASER SIGHT THERMOMETER USES 9VDC ALKALINE BATTERY |
BFQN | DISPLAY TYPE | LIQUID CRYSTAL |
AFGA | OPERATING TEMP RANGE | +0.0/+50.0 DEG CELSIUS |
ASXH | VOLTAGE RATING IN VOLTS | 9.0 DC NOMINAL |