NIIN Output Data
NIIN:
NSN:
Item Name:
HEATER , FLUID , INDUSTRIAL
Definition:
AN APPARATUS DESIGNED TO RAISE THE TEMPERATURE OF A FLUID BY BRINGING IT INTO PROXIMITY WITH ANOTHER FLUID OF HIGHER TEMPERATURE SO THAT HEAT TRANSFER IS EFFECTED BY DIRECT CONTACT OR BY PASSING THOSE FLUIDS THROUGH PIPE(S), TUBE(S), OR COILS WHICH ARE SUBMERGED IN A TANK OF HOT WATER OR STEAM WHICH IS SUPPLIED FROM AN OUTSIDE SOURCE. THE FLUID IS NEVER STORED IN THIS TANK. EXCLUDES AIR CONDITIONING, ELECTRIC FLUID HEATERS, AND REFRIGERATION EQUIPMENT.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
ENMF-320/140 CD | 35795 | A | C | 1 | 6 | ZZ | AC | |
Y901959017 | 35795 | A | 3 | 2 | 6 | ZZ |
CAGE Information
Code | Company |
---|---|
35795 | LESLIE CONTROLS INC. |
Federal Supply Class
Title
HEAT EXCHANGERS AND STEAM CONDEN
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ATYX | CAPACITY RATING | 1800.0 GALLONS PER HOUR |
CBBL | FEATURES PROVIDED | TEMPERATURE REGULATING VALVE |
FEAT | SPECIAL FEATURES | GMODEL 320- SET POINT: 140'F, 30 GPM WITH UNION CONNECTION ON HOT WATER OUTLET AND COLD WATER INLET. SAFETY FEATURE WITH 140 DEG SET POINT USED WITH 1/2 - 3 STEAM CONTROL VALVE. FLANGED HEAT EXCHANGER |