NIIN Output Data
NIIN:
NSN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
57912800-01 | 27963 | R | E | 8 | A | TX | ||
BR230-78B2-12V | 56623 | A | E | 8 | E | ZZ | ||
BR30-72B2-12V | 56623 | A | E | 8 | E | TX | ||
MIL-PRF-83536/15 | 81349 | M | 4 | 1 | E | ZZ | ||
M83536/15-013M | 81349 | M | 2 | 2 | E | ZZ | ||
021-001061 | 26916 | A | E | 8 | A | TX | ||
E410-1311 | 99699 | A | E | 8 | 5 | TX |
CAGE Information
Code | Company |
---|---|
26916 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
27963 | GENERAL DYNAMICS INFORMATION SYSTEMS |
56623 | MICROSEMI CORP.-POWER MANAGEMENT GRO |
81349 | MILITARY SPECIFICATIONS PROMULGATED |
99699 | DRI RELAYS INC. |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
TTQY | TERMINAL TYPE AND QUANTITY | 14 WIRE HOOK ALL FUNCTIONS |
ABMK | OVERALL WIDTH | 1.025 INCHES MAXIMUM |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC RESISTIVE LOAD AND 10.0 AMPERES AC RESISTIVE LOAD |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.010 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC LAMP LOAD AND 2.0 AMPERES AC LAMP LOAD |
FEAT | SPECIAL FEATURES | FAILURE RATE LEVEL 0.1 PERCENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.718 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | AIR |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES DC INDUCTIVE LOAD AND 8.0 AMPERES AC INDUCTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 200.0 AC AND 28.0 DC |
APNP | DUTY TYPE | CONTINUOUS |
ZZZK | SPECIFICATION/STANDARD DATA | 81349-MIL-PRF-83536/15/013M GOVERNMENT SPECIFICATION |
TEST | TEST DATA DOCUMENT | 81349-MIL-PRF-83536 SPECIFICATION |
ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES DC MOTOR LOAD AND 4.0 AMPERES AC MOTOR LOAD |
ADTV | CASE MATERIAL | METAL |
CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
APNA | WINDING DC RESISTANCE RATING | 70.0 OHMS MINIMUM SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 SLOTTED HOLE SINGLE MOUNTING FACILITY |