NIIN Output Data
NIIN:
NSN:
Item Name:
AIR CONDITIONER
Definition:
A SELF-CONTAINED UNIT DESIGNED TO PERFORM THE FUNCTIONS OF COOLING, CIRCULATING, FILTERING, DEHUMIDIFYING OR OTHERWISE PROCESSING OF AIR. IT MAY ALSO BE EQUIPPED TO PERFORM THE ADDITIONAL FUNCTIONS OF HEATING OR HUMIDIFYING. IT MAY BE THE AIR CYCLE TYPE USED IN AIRCRAFT OR THE VAPOR CYCLE TYPE APPLICABLE TO GROUND OR AEROSPACE EQUIPMENT. EXCLUDES ENVIRONMENTAL CONTROL UNIT, PERSONNEL, SELF-CONTAINED.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
9516-4058-1 | 12115 | A | 3 | 2 | 3 | ZZ |
CAGE Information
Code | Company |
---|---|
12115 | DRS ICAS LLC |
Federal Supply Class
Title
AIR CONDITIONING EQUIPMENT
Inclusions:
INCLUDES STORE TYPE UNITS; WINDOW AND ROOM TYPE UNITS; MARINE, AND VEHICULAR AIR CONDITIONING UNITS; AIR CONDITIONING PLANTS AND SYSTEMS.
Exclusions:
EXCLUDES AIR CONDITIONING COMPONENTS (FSC 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ABKW | OVERALL HEIGHT | 4.700 INCHES NOMINAL |
ABFY | OVERALL DEPTH | 18.250 INCHES NOMINAL |
FEAT | SPECIAL FEATURES | LCURRENT TYPE: HEAT PUMP DC - FAN AC; VOLTS: HEAT PUMP 72 NOMINAL - FAN 115.; AMPS: HEAT PUMP 7.0 NOMINAL - FAN 0.16 LOCKED; FREQUENCY: HEAT PUMP N/A - FAN 50/60. UNIT CAN PROVIDE COOLING BY A CHANGE IN POLARITY. |
CYKM | HEATING CAPACITY IN BTU PER HOUR | 1470.0 NOMINAL |
AAXX | MOUNTING TYPE | WALL |
AGAV | END ITEM IDENTIFICATION | UMTE |
ABMK | OVERALL WIDTH | 6.000 INCHES NOMINAL |