NIIN Output Data
Definition:
A UNIT COMPRISING A FIN AND TUBE HEAT TRANSFER ELEMENT, FILTERS AND MAY OR MAY NOT HAVE A MOTOR DRIVEN FAN, INCLOSED IN A CASING FOR THE PURPOSE OF COOLING AND REMOVING MOISTURE FROM THE AIR IN A SPACE WHERE THE UNIT IS INSTALLED. IT MAY INCLUDE ELECTRIC HEATER AND/OR ELECTROSTATIC PRECIPITATOR. EXCLUDES UNITS CONTAINING COMPRESSOR, CONDENSER AND MEANS FOR INTRODUCING AIR FROM OUTSIDE SOURCES.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
V520LR-E | 38450 | A | 3 | 2 | A | ZZ | ||
V520RR-E | 38450 | A | 3 | 2 | A | ZZ | ||
1345D00 | 38450 | A | 7 | 1 | A | ZZ |
CAGE Information
Code | Company |
---|---|
38450 | ENGINEERED COIL COMPANY DBA DRS MARL |
Federal Supply Class
Title
REFRIGERATION AND AIR CONDITIONI
Inclusions:
INCLUDES HEAT EXCHANGER EQUIPMENT; REFRIGERANT STRAINERS; REFRIGERATION COMPRESSORS; AIR CONDITIONING AND REFRIGERATION SERVICING EQUIPMENT, SUCH AS CHARGING AND TESTING MANIFOLDS, LINES AND UNITS; OPERATING COMPONENTS OF REFRIGERATION AND AIR CONDITIONING EQUIPMENT, PLANTS, AND SYSTEMS CLASSIFIED IN CLASSES 4110 AND 4120.
Exclusions:
EXCLUDES REFRIGERATION AND AIR CONDITIONING PLANTS (SEE CLASSES 4110 AND 4120): COLLECTIONS OF REFRIGERATION COMPONENTS "PACKAGED" AS A UNIT INCLUDING A REFRIGERATION COMPRESSOR, CONDENSER, EVAPORATOR, ETC., SPECIFICALLY DESIGNED AND TAILORED FOR APPLICATIONS SUCH AS WALK-IN TYPE REFRIGERATORS. INDIVIDUAL COMPONENTS OF THE "PACKAGED" UNIT WILL BE CLASSIFIED IN CLASS 4130, OR AS OTHERWISE SPECIFICALLY PRESCRIBED BY THE INDEXES AND STRUCTURE OF THE FSC. THE COMPLETE "PACKAGE" UNIT WILL BE CLASSIFIED IN CLASS 4110.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
FAAZ | PHASE | THREE FAN MOTOR |
ACZV | COOLING MEDIUM | CHILLED WATER |
AWLS | CONNECTION TYPE | FLANGE UNION |
FAAZ | PHASE | THREE HEATER |
AWMA | FAN TYPE | CENTRIFUGAL |
AWGJ | TUBE MATERIAL | COPPER |
AWLZ | CASE WITH BUILT-IN CONDENSATE DRAIN PAN | INCLUDED |
AWMB | FAN DRIVE TYPE | DIRECT |
FEAT | SPECIAL FEATURES | MIL-A-24775; REVERSABLE CONNECTIONS (LH/RH); HIGH IMPACT SHOCK AND VIBRATION RESISTANCE HAS LVR (LOW VOLTAGE RELEASE) CAPABILITY |
ABFY | OVERALL DEPTH | 52.000 INCHES NOMINAL |
ELEC | VOLTAGE IN VOLTS | 440.0 FAN MOTOR |
FREQ | FREQUENCY IN HERTZ | 60.0 HEATER |
ELEC | VOLTAGE IN VOLTS | 440.0 HEATER |
CWMQ | HEATER WATTAGE RATING IN KILOWATTS | 2.0 |
ABMK | OVERALL WIDTH | 46.000 INCHES NOMINAL |
AWLQ | COIL TUBE QUANTITY | 1 |
ABKW | OVERALL HEIGHT | 14.000 INCHES NOMINAL |
AWLT | SUPPLY CONNECTION SIZE | 500 IN. OD |
ADTV | CASE MATERIAL | STEEL, GALVANIZED |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 1800.0 |
AGAV | END ITEM IDENTIFICATION | FAN COIL UNIT |
AWLW | RETURN CONNECTION SIZE | 500 IN. OD |
FREQ | FREQUENCY IN HERTZ | 60.0 FAN MOTOR |
AHZX | PRIME MOVER HORSEPOWER RATING | 0.067 |
AWLR | TUBE CIRCUIT QUANTITY | 24 |
ACDC | CURRENT TYPE | AC FAN MOTOR |
CWMP | NOMINAL CAPACITY IN BTU PER HOUR | 30500.0 COOLING AND 30500.0 HEATING |
ACDC | CURRENT TYPE | AC HEATER |