NIIN Output Data
NIIN:
NSN:
Item Name:
TRANSFORMER , POWER AUTOTRANSFORME
Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
PS270049-05 | 35181 | A | 5 | 2 | 4 | 9Z | ||
GSD-250 | 62274 | A | 3 | 2 | 4 | 9Z |
CAGE Information
Code | Company |
---|---|
35181 | CAE INC |
62274 | EMERSON ELECTRIC CO. DIV WHITE-RODGE |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABHP | OVERALL LENGTH | 3.880 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
FEAT | SPECIAL FEATURES | KAUTO TRANSFORMER WHICH HAS ONE WINDING THAT IS TAPPED TO ACHIEVE SPECIFIC OUTPUT VOLTAGE; INPUT CORD LENGTH 5-1/2 FEET MINIMUM AND OUTPUT CORD IS 8 INCHES MINIMUM; MAXIMUM OPERATING TEMPERATURE OF 105 DEGREES C |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AGAV | END ITEM IDENTIFICATION | CP-140 AIRCRAFT |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 2.2 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY INPUT |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
ABKW | OVERALL HEIGHT | 3.630 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 230.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABMK | OVERALL WIDTH | 3.130 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 3.130 INCHES NOMINAL SINGLE GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
TTQY | TERMINAL TYPE AND QUANTITY | 2 CABLE W/CONNECTOR |