Follow Us on Google+

Request A Price Quote:

NIIN Output Data

NIIN:
NSN:
Item Name:
CIRCUIT BREAKER

Definition:

A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.

Reference/Part Number

Part Number CAGE Status RNCC RNVC DAC RNAAC MSDS SADC
JE2S-L2-0015-02N 14502 A 5 1 5 ZZ
5793214 FIND 091 53711 A 5 1 5 ZZ
JE2SL2A001502N 1W134 A 3 2 E ZZ
JE2S-L2-A-0015-02N 74193 H 3 9 5 ZZ

CAGE Information

Code Company
14502 WALTER JIM DOORS DIV OF CELOTEX CORP
53711 NAVAL SEA SYSTEMS COMMAND
1W134 EATON CORP AEROSPACE COMMERCIAL CONT
74193 EATON CORP HEINEMANN PRODUCTS COMMER

Federal Supply Class

Title

CIRCUIT BREAKERS

Inclusions:

INCLUDES CIRCUIT BREAKERS AND CUTOUTS.

Exclusions:

EXCLUDES RELAYS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TTQY TERMINAL TYPE AND QUANTITY 2 SCREW
AKPX POLE QUANTITY 2
ADAT BODY WIDTH 0.750 INCHES NOMINAL
ADAQ BODY LENGTH 2.000 INCHES NOMINAL
AJWX MOUNTING SURFACE TO TERMINAL END DISTANCE 1.030 INCHES NOMINAL
FEAT SPECIAL FEATURES SEALED TOGGLE; MTG: 3/8-32; SERIES TRIP WITH AUX; MEDIUM DELAY STD. INRUSH
CPRF OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS 65.0 DC ALL LOCATIONS
CPLM MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE 15.0 AMPERES DC ALL LOCATIONS
CPRL TRIP RELEASE CHARACTERISTIC TIME DELAY ALL LOCATIONS
ADTV CASE MATERIAL PLASTIC
CPRQ RESET METHOD MANUAL
AXHR MOUNTING FACILITY TYPE AND QUANTITY 4 CLIP
CPRH CIRCUIT PROTECTION TYPE OVERCURRENT ALL LOCATIONS
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY J SERIES CIRCUIT BREAKER - HEINEMAN PRODUCT LINE
CPRT MANUAL ACTUATOR TYPE AND QUANTITY 1 TOGGLE
AAQL BODY STYLE MULTIPOLE-SINGLE ACTUATOR TYPE
AEBP CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH 1.556 INCHES NOMINAL
ABXD BUSHING LENGTH 0.130 INCHES NOMINAL

Similar Parts

JE2S-L2-0015-02N , JE2SL2001502N , 5925-01-545-5932 , 5925015455932 , 015455932 , JE2S-L2-0015-02N , 5793214 FIND 091 , JE2SL2A001502N , JE2S-L2-A-0015-02N ,