NIIN Output Data
NIIN:
NSN:
Item Name:
TEST SET , ELECTRONIC SYSTEMS
Definition:
A TEST SET SPECIFICALLY DESIGNED FOR USE IN MAKING EXAMINATIONS AND PROVIDING DISCRETE EVALUATIONS OF THE OVER-ALL PERFORMANCE OF A SYSTEM(S) OR SUBSYSTEM(S). EXCLUDES TEST SET (1), ANTENNA SYSTEM; TEST SET (1), FIRE CONTROL SYSTEM; TEST SET (1), FLIGHT CONTROL SYSTEM; AND TEST SET (1), TELEMETERING SYSTEM.
Reference/Part Number
Part Number | CAGE | Status | RNCC | RNVC | DAC | RNAAC | MSDS | SADC |
---|---|---|---|---|---|---|---|---|
60502B | 50443 | A | 3 | 2 | 4 | 9Z | ||
60502B | F5056 | A | 5 | 2 | 4 | ZF | ||
60502B | F6117 | A | 5 | 2 | 4 | ZF |
CAGE Information
Code | Company |
---|---|
50443 | AGILENT TECHNOLOGIES INC DBA AGILENT |
F5056 | HEWLETT-PACKARD CENTRE COMPETENCE FR |
F6117 | DASSAULT AVIATION |
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ANPZ | INCLOSURE FEATURE | SINGLE ITEM W/HOUSING |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
FEAT | SPECIAL FEATURES | W/PROGRAMMING INPUTS WHICH ALLOW LOAD CURRENT CONTROL BY ANALOG VOLTAGE; 300 WATT; 0 TO 60 AMP |
AQXY | TEST TYPE FOR WHICH DESIGNED | OVERVOLTAGE, CURRENT, TEMP, POWER AND REVERSE POLARITY PROTECTION |
ACYR | DC VOLTAGE RATING | 60.0 VOLTS NOMINAL |