Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
87557 | LOCKHEED CORP LOCKHEED ELECTRONICS C |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AXGY | MOUNTING METHOD | FLANGE SINGLE GROUP AND SLOT SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | TAP W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED, DOUBLE SHELL |
ADAU | BODY HEIGHT | 4.313 INCHES NOMINAL |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
ABKW | OVERALL HEIGHT | 4.438 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 104.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
ABTD | MOUNTING SLOT WIDTH | 0.196 INCHES NOMINAL SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 20.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 27.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 20.80 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABMK | OVERALL WIDTH | 2.438 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 5.188 INCHES MAXIMUM |
ABHP | OVERALL LENGTH | 5.188 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.438 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 15 TAB, SOLDER LUG |
CRBZ | WINDING OPERATING CURRENT | 2.5 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |