Part Number
Part Number:
NSN:
NIIN:
Item Name:
FAN , CENTRIFUGAL
Definition:
A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE HAVING A CENTRIFUGAL FAN IMPELLER INCLOSED WITHIN A HOUSING. IT IS DESIGNED TO MOVE AIR OR GAS OVER A WIDE RANGE OF VOLUMES AND PRESSURES. THE AIR OR GAS IS DRAWN IN AXIALLY AND DISCHARGED RADIALLY OR DRAWN IN RADIALLY AND DISCHARGED AXIALLY BY CENTRIFUGAL FORCE THROUGH AN OUTLET IN THE HOUSING.
CAGE Information
Code | Company |
---|---|
82877 | ROTRON INCORPORATED DBA AMETEK ROTRO |
Federal Supply Class
Title
FANS, AIR CIRCULATORS, AND BLOWE
Inclusions:
INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.
Exclusions:
EXCLUDES COMBINATION HEATER-FANS (FSC 4520).
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AJLV | OUTLET INSIDE HEIGHT | 2.875 INCHES NOMINAL |
AJLV | OUTLET INSIDE HEIGHT | 2.875 INCHES NOMINAL |
CRWJ | OUTLET LOCATION | BOTTOM |
AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
AKCV | DRIVE TYPE | DIRECT |
CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | 115.0 AC |
STYL | STYLE DESIGNATOR | FIXED, RECTANGULAR OUTLETS |
AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
MATT | MATERIAL | ALUMINUM ALLOY OVERALL |
FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
CQKX | AIR FLOW RATE | 135.0 CUBIC FEET PER MINUTE NOMINAL |
AEHY | AMBIENT TEMP AT FULL RATED POWER | 98.0 DEG CELSIUS |
HGTH | HEIGHT | 7.781 INCHES NOMINAL |
AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 3300.0 |
ABGL | WIDTH | 5.062 INCHES NOMINAL |
CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
AGBD | ELECTRICAL CONNECTION TYPE | CONNECTOR |
CXCB | DISCHARGE DIRECTION | HORIZONTAL |
AJLU | OUTLET INSIDE WIDTH | 1.594 INCHES NOMINAL |
ABRY | LENGTH | 7.219 INCHES NOMINAL |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 FLANGE AND 4 UNTHREADED HOLE |
ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | 0.0 INCHES OF WATER |
CSYL | PRIME MOVER POWER RATING | 36.0 WATTS |
AKNA | INCLOSURE TYPE | PARTIALLY INCLOSED |
ADZC | ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
FAAZ | PHASE | SINGLE |