GENERATOR SET , DIESEL ENGINE , TRAI

Definition:

A GENERATOR SET USING A DIESEL ENGINE AS THE PRIME MOVER, THE COMPLETE UNIT BEING MOUNTED ON A TRAILER IN ORDER TO PROVIDE A MOBILE POWER SOURCE.

CAGE Information

Code Company
30554 DEPARTMENT OF DEFENSE PROJECT MANAGE

Federal Supply Class

Title

GENERATORS AND GENERATOR SETS, E

Inclusions:

INCLUDES ENGINE, TURBINE, WIND, AND HAND DRIVEN GENERATOR SETS AND AUXILIARY AIRCRAFT GENERATORS.

Exclusions:

EXCLUDES MOTOR-CONVERTERS; MOTOR-GENERATOR SETS; ENGINE GENERATORS; ENGINE ACCESSORY GENERATORS.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AMWJ WINTERIZATION FEATURE INCLUDED
CXCY PART NAME ASSIGNED BY CONTROLLING AGENCY GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED
FEAT SPECIAL FEATURES A TRAILER MOUNTED GENERATOR SET THAT PRODUCES 10KW (400HZ) 8.3 KW OF CONTINUOUS POWER AT 0.8 PF AT 4000 FT ELEVATION AT 95 DEGREE F, CAPABLE OF 400 HZ OPERATION, SINGLE PHASE, 2 WIRE 120-VOLT AND SINGLE PHASE, 3 WIRE 120/240-VOLT, OR PHASE, 4 WIRE 120/208-VOLT OUTPUT, WILL OPERATE FROM -50 DEGREES F ( WITH WINTERIZATION KIT, OR -25 DEGREE F WITH OUT0 TO 135 DEGREES F
FTLD FUNCTIONAL DESCRIPTION AMMPS POWER UNIT PU-2012, CONSISTS OF ONE MEP-1041 GENERATOR SET, DIESEL ENGINE DRIVEN OR JP-8 FUELS AND USES STANDARD MILITARY OIL, LUBRICANTS AND COOLANTS, MOUNTED ON A MODIFIED LTT TRILER, MODIFIED TO SECURE AND TRANSPORT THE GENERATOR SET
FAAZ PHASE SINGLE/THREE
RTSE RELATIONSHIP TO SIMILAR EQUIPMENT 10KW AMMPS POWER UNIT WILL REPLACE THE 10 KW TQG POWER UNIT
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL
AGAV END ITEM IDENTIFICATION GENERATOR SET, DIESEL ENGINE, TRAILER MOUNTED
AYHD POWER FACTOR IN PERCENT 0.8
AYGY AC WATTAGE RATING 10.0 KILOWATTS AND 8.3 KILOWATTS
ACDC CURRENT TYPE AC

Similar Parts