Definition:
AN ITEM DESIGNED PRIMARILY FOR THE CONDUCTION OF RADIO FREQUENCY ENERGY, AND CONSISTING OF TWO OR MORE CONDUCTORS SUPPORTED IN FIXED SPATIAL RELATIONSHIP(S) ALONG THEIR OWN LENGTH. SINCE THE CHARACTERISTIC IMPEDANCE OF THE LINE IS DETERMINED BY THE SPATIAL RELATIONSHIPS OF THE CONDUCTORS, WHICH ARE SUFFICIENTLY RIGID TO MAINTAIN THESE RELATIONSHIPS BETWEEN SUPPORTS, THE CONFIGURATION OF THE ITEM IS USUALLY NOT SUSCEPTIBLE TO MECHANICAL MANIPULATION; THAT IS, IT IS NOT NORMALLY FLEXIBLE. INCLUDES A SINGLE CONDUCTOR INCLOSED IN AN OUTER CONCENTRIC CONDUCTOR (COAXIAL) OR TWO OR MORE CONDUCTORS LAID PARALLEL. ALL TYPES HAVE LOW LOSS OR SPECIAL CHARACTERISTICS AT HIGH FREQUENCIES. MAY INCLUDE FITTINGS OR TERMINATIONS. FOR ITEMS HAVING CONTINUOUS HOMOGENEOUS DIELECTRIC, SEE CABLE, RADIO FREQUENCY. SEE ALSO LINE SECTION, RADIO FREQUENCY TRANSMISSION.
CAGE Information
Code | Company |
---|---|
34228 | KOLLMORGEN CORPORATION DBA KOLLMORGE |
Federal Supply Class
Title
ANTENNAS, WAVEGUIDES, AND RELATE
Inclusions:
INCLUDES AERIALS; MASTS; TOWER EQUIPMENT; ATTENUATORS; COUPLERS; TRANSMISSION LINES.
Exclusions:
EXCLUDES TOWER STRUCTURES.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AJDD | CHARACTERISTIC IMPEDANCE IN OHMS | 50.0 |
AQCE | ACCOMMODATED CONDUCTOR TYPE | COAXIAL |
AQBA | INSULATION SPACER OUTSIDE DIAMETER | 0.116 INCHES MINIMUM AND 0.118 INCHES MAXIMUM |
ABHE | OUTSIDE DIAMETER | 0.140 INCHES MINIMUM AND 0.142 INCHES MAXIMUM |
AQBB | TERMINATION CONTROLLING AGENCY | KOLLMORGEN CORP |
AAJU | OVERALL LENGTH | 11.250 INCHES |
ACVL | CONDUCTOR SIZE | 19 AWG |
MATL | MATERIAL | COPPER, WW-T-799 |
AQAZ | INSULATION SPACER MATERIAL | PLASTIC, POLYTETRAFLUOROETHYLENE |
APZD | INSULATION SPACER SHAPE | ROUND |
AQBD | TERMINAL FITTING | INCLUDED |
APZC | OUTER CONDUCTOR | INCLUDED |
APYQ | CONDUCTOR MATERIAL | COPPER |
AMQN | CONDUCTOR QUANTITY | 1 |
AJDF | TERMINATION IDENTIFICATION | 885C052197 |
AQRW | CONDUCTOR SURFACE TREATMENT | SILVER PLATED |