Part Number
Definition:
A TEST INSTRUMENT WHICH IS DESIGNED TO GIVE VISUAL INDICATIONS ON A CATHODE RAY TUBE OF INSTANTANEOUS VALUES AND VARIATIONS IN ELECTRICAL VOLTAGE. IT CAN ALSO BE USED TO INDICATE ANY QUANTITY WHICH CAN BE CONVERTED INTO TERMS OF ELECTRICAL POTENTIAL. IT MAY INCLUDE AN INTEGRAL PULSE GENERATOR, THE OUTPUT OF WHICH CAN BE USED TO TRIGGER AN EXTERNAL COMPONENT; BE TRIGGERED BY PULSES FROM AN EXTERNAL SOURCE, OR IT MAY UTILIZE A SPECIAL TYPE OF MULTIGUN CATHODE RAY TUBE AND CIRCUITRY WHICH PERMITS A TRACE(S) TO BE SUSTAINED AND DISPLAYED INDEFINITELY, AND THE TRACE(S) MAY BE ERASED WHEN DESIRED. FOR ITEMS WHICH ARE NOT SEPARABLE AND OPERABLE WHEN DETACHED FROM EQUIPMENT OF WHICH THEY ARE A PART (BUILT INTO OPERATIONAL EQUIPMENT), SEE INDICATOR (2) (AS MODIFIED); MONITOR (AS MODIFIED); AND RECORDER (AS MODIFIED). SEE ALSO OSCILLOGRAPH.
CAGE Information
Code | Company |
---|---|
80058 | JOINT ELECTRONICS TYPE DESIGNATION S |
Federal Supply Class
Title
ELECTRICAL AND ELECTRONIC PROPER
Inclusions:
INCLUDES TEST LEADS AND TEST LEAD ATTACHMENTS; TEST INSTRUMENTS DESIGNED FOR COMMUNICATION EQUIPMENT; TEST INSTRUMENTS DESIGNED FOR USE WITH ELECTRONIC EQUIPMENT CLASSIFIED IN TWO OR MORE FSC GROUPS.
Exclusions:
EXCLUDES RADIAC EQUIPMENT
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
BHDP | FREQUENCY RESPONSE RATING | PROVIDED |
BHDD | AMPLIFIER DEFLECTION SENSITIVITY PROVISION | PROVIDED |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM AND 400.0 HERTZ MAXIMUM |
BHFT | CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
BHDT | AMPLIFIER INPUT IMPEDANCE RATING PROVISION | PROVIDED |
BGQM | GENERATOR DRIVEN FEATURE | NOT INCLUDED |
ABMK | OVERALL WIDTH | 8.750 INCHES NOMINAL |
BHDR | Y-AXIS FREQUENCY RESPONSE RATING | 0.0 KILOHERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM |
BGQP | SWEEP FREQUENCY RANGE | +2.0/+30000.0 HERTZ |
AKYD | ACCESSORY COMPONENTS AND QUANTITY | 1 BEZEL,1 FILTER COLOR,1 SCALE ILLUMINATED GRANDULATED |
BGSD | EXPANDED SWEEP | PROVIDED |
BGQL | SWEEP CIRCUITS | INCLUDED |
BHDY | Z-AXIS INPUT IMPEDANCE RATING | 0.2 MEGOHMS NOMINAL |
BHFH | TRACE STORAGE TUBE | NOT INCLUDED |
BHDG | HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | 100.0 MILLIVOLTS ANY ACCEPTABLE OUTSIDE DIAMETER |
ATES | BEAM QUANTITY | 1 |
ABHP | OVERALL LENGTH | 19.500 INCHES NOMINAL |
BHDN | DIRECT CONNECTION HORIZONTAL DEFLECTION SENSITIVITY VOLTAGE RATING | 15.0 VOLTS MINIMUM RMS PER INCH AND 18.0 VOLTS MAXIMUM RMS PER INCH |
BHFF | CALIBRATED SCREEN SCALE | NOT INCLUDED |
ABKW | OVERALL HEIGHT | 13.500 INCHES NOMINAL |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | W/SPARES |
BHDM | DIRECT CONNECTION VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | 12.0 VOLTS CW OUTSIDE DIAMETER AND 14.0 VOLTS PEAK OUTSIDE DIAMETER |
BHDL | PLATE DIRECT CONNECTION DEFLECTION SENSITIVITY PROVISION | PROVIDED |
BHDX | Y-AXIS INPUT IMPEDANCE RATING | 2.0 MEGOHMS NOMINAL |
BGQK | SCREEN SIZE | 5.000 IN. |
BGQQ | SINGLE TRIGGER SWEEP DURATION | 0.5 SECONDS MINIMUM AND 0.033 MILLISECONDS MAXIMUM |
AXGY | MOUNTING METHOD | TABLE |
BHDQ | X-AXIS FREQUENCY RESPONSE RATING | 0.0 KILOHERTZ MINIMUM AND 100.0 KILOHERTZ MAXIMUM |
AMSE | VOLTAGE RATING | 115.0 VOLTS MINIMUM AND 230.0 VOLTS MAXIMUM |
BHDH | INPUT INTENSITY MODULATION FEATURE | NOT PROVIDED |
BGRZ | TRIGGER SWEEP VOLTAGE AMPLITUDE RATING | 180.0 VOLTS MAXIMUM |
ACDC | CURRENT TYPE | AC |
BHDF | VERTICAL DEFLECTION SENSITIVITY VOLTAGE RATING | 9.0 MILLIVOLTS NOMINAL RMS PER INCH |
BGQN | SWEEP CIRCUIT TYPE | ANY ACCEPTABLE |
BHDW | X-AXIS INPUT IMPEDANCE RATING | 2.0 MEGOHMS NOMINAL |
BGSC | TRIGGER SWEEP MARKER INTERVALS | VARIABLE SWEEP |
FAAZ | PHASE | SINGLE |
BGSB | TRIGGER SWEEP POLARITY SWITCH | INCLUDED |