Part Number
Definition:
A RIGID OR FLEXIBLE TUBING HAVING UNIFORM INSIDE AND OUTSIDE DIAMETERS IN THE OVERALL LENGTH. IT IS SPECIFICALLY DESIGNED TO PREVENT ANY UNDESIRABLE FLOW OF CURRENT BETWEEN CONDUCTORS AND OTHER OBJECTS. INCLUDES SHRINKABLE TYPE TUBING, ITEMS IN BULK AND IN SPECIFIC FABRICATED LENGTHS (CUT TO SIZE). EXCLUDES ITEMS NOT HAVING RATED ELECTRICAL CHARACTERISTICS. ALSO EXCLUDES BUSHING, SLEEVE; CABLE NIPPLE, ELECTRICAL; CONDUIT (AS MODIFIED); INSULATION SLEEVING, ELECTRICAL, SPECIAL PURPOSE; INSULATION SLEEVING, THERMAL; SLEEVE, MARKER, CABLE; SLEEVING, TEXTILE, ELECTRICAL; TUBING, GLASS; AND TUBING, NONMETALLIC.
CAGE Information
Code | Company |
---|---|
Z8518 | BAE SYSTEMS AUSTRALIA LAND DIVISION |
Federal Supply Class
Title
ELECTRICAL INSULATORS AND INSULA
Inclusions:
INCLUDES TUBE, KNOB, CLEAT, STRAIN, AND STANDOFF INSULATORS; FEED THRU INSULATORS; BEAD INSULATORS; VARNISH CAMBRIC TAPE; FRICTION TAPE.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
MATL | MATERIAL | PLASTIC,POLYOLEFIN,MIL-I-23053/16 |
HUES | COLOR | BLACK |
STYL | STYLE DESIGNATOR | SHRINKABLE |
ADZC | ENVIRONMENTAL PROTECTION | CORROSION RESISTANT AND MILDEW RESISTANT |
FLEX | FLEXIBILITY | FLEXIBLE |
ABHP | OVERALL LENGTH | ANY ACCEPTABLE |
UKBG | DIELECTRIC MATERIAL VOLTAGE RATING PER UNIT THICKNESS | 300.0 VOLTS PER MIL /0.001 INCH/ |
AGAU | HEAT SHRINKAGE RATING IN PERCENT | 50.0 |
CQBC | MINIMUM TENSILE STRENGTH | 1700 POUNDS PER SQUARE INCH |
AFZM | RECOVERED INSIDE DIAMETER | 0.375 INCHES MAXIMUM |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AFZN | RECOVERED WALL THICKNESS | 0.057 INCHES NOMINAL |
AFZL | EXPANDED INSIDE DIAMETER | 0.750 INCHES MINIMUM |
ABJH | TEMP RATING | -75.0 DEG CELSIUS AND 120.0 DEG CELSIUS |