SOLENOID , ELECTRICAL
Definition:
AN ITEM CONSISTING OF ONE OR MORE COILS SURROUNDING AN IRON CORE. THE COIL(S) AND THE CORE ARE MOVEABLE IN RELATION TO EACH OTHER. THE AXIAL OR ROTARY MOVEMENT IS A RESULT OF THE MAGNETIC FLUX OF THE COIL. IT IS DESIGNED TO CONVERT ELECTRICAL ENERGY INTO MECHANICAL ENERGY. IT DOES NOT INCLUDE SWITCH CONTACTS. SEE ALSO RELAY, ELECTROMAGNETIC, AND ELECTROMAGNETIC ACTUATOR.
CAGE Information
Code | Company |
---|---|
56232 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AFUR | ACTUATOR DIAMETER | 0.250 INCHES NOMINAL |
APNP | DUTY TYPE | INTERMITTENT |
ADTY | CASE SURFACE TREATMENT | CADMIUM |
CMLP | THREAD QUANTITY PER INCH | 32 MOUNTING FACILITY STUD |
APCC | ELECTRICAL RESISTANCE | 30.50 OHMS NOMINAL |
CNXT | ACTUATOR STROKE TYPE | ROTARY |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
APAF | MAGNETIC COIL QUANTITY | 1 |
AAJD | THREAD CLASS | 2A MOUNTING FACILITY STUD |
APXH | TERMINAL LOCATION | CIRCUMFERENCE |
ASXH | VOLTAGE RATING IN VOLTS | 50.0 DC MAXIMUM |
ARQE | ELECTRIC POWER RATING | 8.00 WATTS NOMINAL |
CNXX | POWER TAKEOFF CONNECTION TYPE | PLAIN |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.500 INCHES NOMINAL |
ADTV | CASE MATERIAL | STEEL |
BKPH | TORQUE RATING AND TYPE | 0.50 INCH-POUNDS STARTING AND 14.30 INCH-POUNDS END |
CSQY | ROTATION DIRECTION AND ENERGIZING STROKE IN ANGULAR DEG | 95.0 CLOCKWISE |
AAQL | BODY STYLE | ARMATURE END ACTUATOR |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES MOUNTING FACILITY STUD |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
ADAU | BODY HEIGHT | 1.047 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 90.0 DEG CELSIUS |
ABPM | BODY DIAMETER | 1.906 INCHES NOMINAL |
THSD | THREAD SERIES DESIGNATOR | UNC MOUNTING FACILITY STUD |
ADZC | ENVIRONMENTAL PROTECTION | ANY ACCEPTABLE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED STUD |