Part Number
Part Number:
NSN:
NIIN:
Item Name:
CIRCUIT BREAKER
Definition:
A DEVICE WITH MEANS OTHER THAN FUSES FOR AUTOMATICALLY OPENING THE CIRCUIT IN WHICH IT IS INSTALLED WHEN THE CURRENT VARIES FROM THE PREDETERMINED VALUE FOR WHICH THE DEVICE IS SET. MAY INCLUDE PROVISIONS FOR MANUAL OPERATION. AT LEAST ONE SET OF CONTACTS MUST BE IN SERIES WITH THE ACTUATING ELEMENT(S). A COMBINATION OF SEMICONDUCTOR AND PASSIVE DEVICES MAY BE USED IN LIEU OF CONTACTS. FOR AUTOMATICALLY OPERATED ITEMS IN WHICH THE ACTUATING (TRIPPING) ELEMENT AND CONTACTS ARE NOT IN SERIES, SEE RELAY (AS MODIFIED). FOR ITEMS WHICH ARE OPERATED BOTH MANUALLY AND AUTOMATICALLY BUT THE ACTUATING ELEMENTS AND CONTACT ARE NOT IN SERIES, SEE RELAY-SWITCH. EXCLUDES CIRCUIT BREAKER BOX AND MAGNETO "BREAKER" ASSEMBLIES. SEE ALSO SWITCH (AS MODIFIED); AND CONTROLLER.
CAGE Information
Code |
Company |
79405 |
WOOD ELECTRIC OPERATIONS POTTER AND |
Characteristics (Decoded)
MRC |
Requirements Statement |
Clear Text Reply |
CPRG |
MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS |
3500.0 AC SINGLE LOCATION AND 6000.0 DC SINGLE LOCATION |
CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
CPRH |
CIRCUIT PROTECTION TYPE |
OVERCURRENT SINGLE LOCATION |
AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED BUSHING |
CPRN |
ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT |
138.0 SINGLE LOCATION |
PKWT |
UNPACKAGED UNIT WEIGHT |
2.000 OUNCES |
AAQL |
BODY STYLE |
SINGLE POLE TYPE |
ADAT |
BODY WIDTH |
0.750 INCHES NOMINAL |
AEBP |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH |
0.704 INCHES NOMINAL |
CPSM |
INTERNAL TRIP RELEASE CONFIGURATION |
SERIES TRIP SINGLE LOCATION |
AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.812 INCHES NOMINAL |
TTQY |
TERMINAL TYPE AND QUANTITY |
2 TAB W/SCREW |
CPLM |
MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE |
35.0 AMPERES AC SINGLE LOCATION AND 35.0 AMPERES DC SINGLE LOCATION |
CPRR |
MAIN CONTACT TRIPPING MECHANISM TYPE |
TRIP FREE |
THSD |
THREAD SERIES DESIGNATOR |
UNS |
CQWN |
TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT |
15.000 MINIMUM AT 200 PCT SINGLE LOCATION AND 55.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
ADTV |
CASE MATERIAL |
PLASTIC |
AKPX |
POLE QUANTITY |
1 |
CPRQ |
RESET METHOD |
MANUAL |
ADAQ |
BODY LENGTH |
1.094 INCHES NOMINAL |
CPRF |
OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS |
115.0 AC SINGLE LOCATION AND 32.0 DC SINGLE LOCATION |
CPRJ |
TRIP RELEASE METHOD |
THERMAL SINGLE LOCATION |
CQXF |
INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED |
SHOCKPROOF AND VIBRATIONPROOF |
CPRT |
MANUAL ACTUATOR TYPE AND QUANTITY |
1 PUSH-PULL |
CPRW |
ACTUATOR FUNCTION |
TRIP-RESET |
CPRX |
ACTUATOR POSITION DESIGNATION |
AT POLE ONE |
FREQ |
FREQUENCY IN HERTZ |
400.0 SINGLE LOCATION |
CMLP |
THREAD QUANTITY PER INCH |
32 |
CPRL |
TRIP RELEASE CHARACTERISTIC |
TIME DELAY SINGLE LOCATION |
CRCF |
TRIP RELEASE AMBIENT TEMP RATING |
25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
ABXD |
BUSHING LENGTH |
0.250 INCHES NOMINAL |