Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
21562 GENERAL DYNAMICS OTS AEROSPACE INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
TTQY TERMINAL TYPE AND QUANTITY 12 PIN
ADAT BODY WIDTH 1.154 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 22.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
ADAQ BODY LENGTH 1.165 INCHES NOMINAL
CRBZ WINDING OPERATING CURRENT 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY
AXGY MOUNTING METHOD TAB SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 500.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
ACZF MAXIMUM TRANSFORMER POWER RATING 50.0 WATTS SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 140.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT
ACZB FREQUENCY RATING 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 65.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.073 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AEHZ MAXIMUM OPERATING TEMP 120.0 DEG CELSIUS
TEST TEST DATA DOCUMENT 16340-11-00034 DRAWING
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
CRBZ WINDING OPERATING CURRENT 1.9 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT SINGLE PRIMARY
ABKW OVERALL HEIGHT 1.476 INCHES NOMINAL
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 0.354 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AFHM MOUNTING TAB WIDTH 0.012 INCHES NOMINAL
CWJS WINDING OPERATING VOLTAGE 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 43.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CRBZ WINDING OPERATING CURRENT 1.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 4TH SECONDARY

Similar Parts

11-00034-001 , 1100034001 , 5950-01-324-4310 , 5950013244310 , 013244310