Follow Us on Google+

Request A Price Quote:

Part Number

Part Number:
NSN:
NIIN:
Item Name:
FAN , TUBEAXIAL

Definition:

A NONPOSITIVE DISPLACEMENT MECHANICAL DEVICE WITHOUT GUIDE VANES AND HAVING AN AXIAL FAN IMPELLER INCLOSED WITHIN A TUBULAR HOUSING. IT IS DESIGNED PRIMARILY FOR DUCT INSTALLATION TO MOVE AIR OR GAS AXIALLY OVER A WIDE RANGE OF VOLUMES AT MEDIUM PRESSURES.

CAGE Information

Code Company
33214 AYDIN CORP AYDIN CONTROLS DIV

Federal Supply Class

Title

FANS, AIR CIRCULATORS, AND BLOWE

Inclusions:

INCLUDES WALL TYPE FANS; PEDESTAL TYPE FANS; HOUSEHOLD TYPE AND ATTIC TYPE EXHAUST FANS; FLOOR FANS; FORGED DRAFT EXHAUST AND DISPOSAL KITS; FANS, AIR CIRCULATORS, AND BLOWER EQUIPMENT, WHETHER DESIGNATED AS "INDUSTRIAL" OR "NONINDUSTRIAL" BY APPLICATION AND/OR USE.

Exclusions:

EXCLUDES COMBINATION HEATER-FANS (FSC 4520).

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
ADNK FLOW DIRECTION INWARD
MATT MATERIAL PLASTIC BLADE
AYSY ROTATION DIRECTION FOR WHICH DESIGNED COUNTERCLOCKWISE
ABRY LENGTH 2.000 INCHES NOMINAL
CWLX HOUSING INSIDE DIAMETER 6.500 INCHES NOMINAL
AKNA INCLOSURE TYPE FULLY INCLOSED
AGAV END ITEM IDENTIFICATION AN/SQQ-34 CARRIER BASED ASW MODULE; DEEP SUBMERGENCE SYSTEMS PROGRAMS (DSSP); OVER THE HORIZON BACK SCANNER (OTH-B) PROGRAM (AN/FPS-118); TELETYPE, MODEL 28; MISSILE, AIR-TO-AIR, PHOENIX (AIM-54); SUPPORT EQUIPMENT, B-52 AIRCRAFT; TICONDEROGA CLASS CG (47); SUPPORT EQUIPMENT, MX PEACEKEEPER MISSILE; VIRGINIA CLASS CGN (41); POWER CONDITIONING CONTINUATION INTERFACE EQUIP (PCCIE)
STYL STYLE DESIGNATOR FIXED
AKCV DRIVE TYPE DIRECT
CSBH VOLTAGE IN VOLTS AND CURRENT TYPE 115.0 AC
CSYL PRIME MOVER POWER RATING 31.0 WATTS
AKDJ PRIME MOVER TYPE ELECTRIC MOTOR
FREQ FREQUENCY IN HERTZ 50.0 AND 60.0
AGBD ELECTRICAL CONNECTION TYPE TERMINAL BLOCK
FEAT SPECIAL FEATURES FEATHERED EDGE BLADES
ABBB SPEED ADJUSTMENTS SINGLE SPEED
AJLY STATIC PRESSURE AT SPECIFIED AIR FLOW RATE 0.0 INCHES OF WATER
AEQC OPERATING SPEED AT RATED CAPACITY IN RPM 2850.0 AND 3350.0
MATT MATERIAL ALUMINUM ALLOY HOUSING
CQKX AIR FLOW RATE 240.000 CUBIC FEET PER MINUTE MINIMUM
FAAZ PHASE SINGLE
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 RIM AND 4 UNTHREADED HOLE

Similar Parts

116-028-001 , 116028001 , 4140-01-066-7883 , 4140010667883 , 010667883