Part Number
Definition:
AN ELECTROMAGNETICALLY ACTUATED SWITCH HAVING CONTACT WIPERS WHICH ARE SUCCESSIVELY ROTATED OVER FIXED BANK CONTACTS. THE CONTACT WIPERS ARE PROGRESSIVELY ADVANCED OVER THE FIXED BANK CONTACTS THROUGH A REPETITIVE SERIES OF STEPPING OPERATIONS. THE STEPPING OPERATION MAY BE A CONTINUOUS FORWARD ROTATION ACTING THROUGH 360 DEGREES TO RETURN TO ITS NORMAL UNOPERATED POSITION OR IT MAY BE DESIGNED TO INCLUDE AN ELECTROMAGNETIC AND/OR MECHANICAL MEANS FOR RELEASING AND RESETTING THE SWITCH TO ITS RELEASED POSITION FOR A SUBSEQUENT OPERATION. THE CONTACT WIPERS MAY BE MECHANICALLY HELD IN CONTACT WITH THE FIXED BANK CONTACTS AFTER THE ARMATURE OF THE ACTUATING COIL HAS RELEASED. THE SWITCH MAY BE RELEASED AT THE END OF ITS TRAVEL OR AT ANY INTERMEDIATE POSITION. IT INCLUDES ITEMS DESIGNED WITH TWO ELECTROMAGNETIC ACTUATORS THAT ENABLE THE SWITCH TO OPERATE IN EITHER DIRECTION. FOR ITEMS HAVING THE DUAL FUNCTION OF A SWITCH AND A RELAY ASSEMBLED TOGETHER ON A COMMON MOUNTING, SEE RELAY-SWITCH. FOR OTHER THAN ELECTROMAGNETICALLY ACTUATED SWITCHES WHOSE CONTACT WIPERS ARE MANUALLY ROTATED OVER FIXED BANK CONTACTS, SEE SWITCH, ROTARY. EXCLUDES RELAY, ROTARY AND SWITCH, TELEPHONE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
26512 | NORTHROP GRUMMAN SYSTEMS CORPORATION |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
ALGC | MOUNTING CONFIGURATION | 4 MTG STUDS NO. 8-32 THD 1.750 IN. BY 4.310 IN. MTG CENTERS |
ALGC | MOUNTING CONFIGURATION | 4 MTG STUDS NO. 8-32 THD 1.750 IN. BY 4.310 IN. MTG CENTERS |
APAA | CONTACT CURRENT RATING | 3.0 AMPERES |
ABHP | OVERALL LENGTH | 5.070 INCHES MINIMUM AND 5.110 INCHES MAXIMUM |
APAF | MAGNETIC COIL QUANTITY | 1 |
ACDC | CURRENT TYPE | DC |
ANZZ | WIPER CONTACT QUANTITY PER BANK LEVEL | 1 |
ABKW | OVERALL HEIGHT | 4.020 INCHES MINIMUM AND 4.100 INCHES MAXIMUM |
ANZY | CONTACT QUANTITY PER BANK LEVEL | 10 |
APAD | NONBRIDGING LEVEL QUANTITY | 5 |
ABFY | OVERALL DEPTH | 2.450 INCHES MINIMUM AND 2.490 INCHES MAXIMUM |
AMSE | VOLTAGE RATING | 24.0 VOLTS NOMINAL |
ADJH | MOUNTING METHOD | STUD |
APCC | ELECTRICAL RESISTANCE | 24.0 OHMS NOMINAL |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AS DIFFERENTIATED BY THE SOURCE CONTROL DWG NO. |
APAG | COIL TYPE | DRIVE |
ANZX | BANK LEVEL QUANTITY | 5 |
APAB | CONTACT TYPE | NONBRIDGING |