Part Number
Definition:
A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
94271 | LOCKHEED MARTIN CORPORATION DBA LOCK |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRBZ | WINDING OPERATING CURRENT | 30.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER SINGLE COMPONENT SINGLE SECONDARY AND 50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE SECONDARY |
CRTL | CRITICALITY CODE JUSTIFICATION | ZZZY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 PIN |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ZZZY | REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | AREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL. MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP |
FEAT | SPECIAL FEATURES | ITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO3858 |
CWJS | WINDING OPERATING VOLTAGE | 4.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 2ND PRIMARY |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 0.039 POUNDS |
AEHZ | MAXIMUM OPERATING TEMP | 85.0 DEG CELSIUS |
CWJS | WINDING OPERATING VOLTAGE | 9.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE SECONDARY AND 19.00 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 5.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST PRIMARY |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQLC | WINDING TAP LOCATION (NON-CORE) | CENTER TAP SINGLE COMPONENT 1ST PRIMARY |
ACZB | FREQUENCY RATING | 13.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 17.0 KILOHERTZ MAXIMUM SINGLE COMPONENT |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAR | BODY OUTSIDE DIAMETER | 1.140 INCHES MAXIMUM |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 2.09 VOLT-AMPERE SINGLE COMPONENT |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
CQLC | WINDING TAP LOCATION (NON-CORE) | MULTIPLE TAPS W/CENTER TAP SINGLE COMPONENT SINGLE SECONDARY |
ADAQ | BODY LENGTH | 0.430 INCHES MAXIMUM |