Part Number
Part Number:
NSN:
NIIN:
Item Name:
SWITCH , THERMOSTATIC
Definition:
A SWITCH THAT IS ACTUATED BY CHANGES IN AMBIENT TEMPERATURE. EXCLUDES CIRCUIT BREAKER; CONTROL, TEMPERATURE (AS MODIFIED); FUSE (AS MODIFIED); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; AND THERMOSTAT, FLOW CONTROL. SEE ALSO CONTROL, TEMPERATURE (AS MODIFIED) AND REGULATOR, TEMPERATURE (AS MODIFIED).
CAGE Information
Code | Company |
---|---|
18876 | U S ARMY AVIATION AND MISSILE COMMAN |
Federal Supply Class
Title
SWITCHES
Inclusions:
INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.
Exclusions:
EXCLUDES SWITCHGEAR.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CSCF | TERMINAL TYPE | QUICK DISCONNECT, MALE |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
CTHF | CONTACT LOAD CURRENT RATING | 1.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
ABKW | OVERALL HEIGHT | 1.380 INCHES MAXIMUM |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
AXGY | MOUNTING METHOD | BRACKET AND SLOT AND UNTHREADED HOLE |
ABHP | OVERALL LENGTH | 2.680 INCHES MAXIMUM |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR LIQUID |
ABMK | OVERALL WIDTH | 2.070 INCHES MAXIMUM |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT |
CTYX | CONTACT STIMULUS RATING | 27.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 35.50 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
STYL | STYLE DESIGNATOR | RECTANGULAR |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 30.0 DC AT SEA LEVEL SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.218 INCHES NOMINAL |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 2.220 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
AEVT | CAPILLARY TUBE LENGTH | 24.00 INCHES NOMINAL |
ADAQ | BODY LENGTH | 1.740 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.218 INCHES NOMINAL |