Definition:
A TRANSFORMER WHICH INCORPORATES THE PRIMARY AND SECONDARY FUNCTIONS INTO A SINGLE WINDING, WHICH IS COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, AND IS DESIGNED TO CHANGE THE RELATIONSHIP OF VOLTS AND AMPERES BETWEEN THE ENTIRE WINDING AND ITS TAPS. INCLUDES MULTIPLE WINDING TRANSFORMERS OF LIKE DESIGN AND ITEMS IN WHICH A VARIATION OF THE TURNS RATIO OR INDUCTIVE RATIO OF INDUCTIVE COUPLING IS ACCOMPLISHED BY CONNECTION TO FIXED TERMINALS. ALSO, INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO IN PROGRESSIVE INCREMENTS, BY MEANS OF A SHAFT, VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OF SIMILAR DESIGN. EXCLUDES TRANSFORMER (1), POWER; TRANSFORMER (1), PULSE.
CAGE Information
Code | Company |
---|---|
58474 | SUPERIOR ELECTRIC HOLDING GROUP LLC |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
ABMK | OVERALL WIDTH | 9.250 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 5.530 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY, VARIABLE AUTOTRANSFORMER TYPE SINGLE COMPONENT |
ABTD | MOUNTING SLOT WIDTH | 0.250 INCHES NOMINAL SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
ABHP | OVERALL LENGTH | 14.188 INCHES NOMINAL |
CWJS | WINDING OPERATING VOLTAGE | 0.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT AND 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CRMJ | WINDING POWER RATING | 2.6 K1LOVOLT-AMPERES SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
ACZX | WINDING SHIELDING METHOD | EXTERNAL INCLOSURE SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY INPUT |
PKWT | UNPACKAGED UNIT WEIGHT (NON-CORE) | 41.000 POUNDS |
CRBZ | WINDING OPERATING CURRENT | 22.0 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY OUTPUT |
AARD | DUMMY TERMINAL QUANTITY (NON-CORE) | 2 |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 3 SCREW |
ABKW | OVERALL HEIGHT | 10.062 INCHES NOMINAL |