Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
58614 | TYCO ELECTRONICS CORPORATION DBA CII |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
AKDX | WINDING QUANTITY | 1 |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.250 INCHES NOMINAL |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 1.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 11 WIRE HOOK ALL FUNCTIONS |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 2.812 INCHES NOMINAL |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS |
APNP | DUTY TYPE | CONTINUOUS |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE MOUNTING FACILITY |
ABHP | OVERALL LENGTH | 1.562 INCHES NOMINAL |