Part Number
Part Number:
NSN:
NIIN:
Item Name:
RELAY , ELECTROMAGNETIC
Definition:
A RELAY WHICH IS ACTUATED BY THE EFFECT OF A MAGNETIC FIELD DEVELOPED BY THE CURRENT IN ITS ENERGIZING COIL(S). INCLUDES SOLENOID AND ARMATURE TYPES. EXCLUDES CONTACTOR, MAGNETIC; RELAY, METER MOVEMENT; RELAY, MOTOR DRIVEN; RELAY, REED; RELAY, RESONANT REED; RELAY, ROTARY; AND SWITCH, STEPPING.
CAGE Information
Code | Company |
---|---|
30003 | NAVAL AIR SYSTEMS COMMAND |
Federal Supply Class
Title
RELAYS AND SOLENOIDS
Inclusions:
INCLUDES ELECTROMAGNETIC ACTUATORS.
Exclusions:
EXCLUDES CONTRACTORS.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 DC |
AKDX | WINDING QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.227 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.237 INCHES MAXIMUM FIRST MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 16 WIRE HOOK ALL FUNCTIONS |
AGAV | END ITEM IDENTIFICATION | A-7E ACFT |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES DC RESISTIVE LOAD |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 101.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
ABMK | OVERALL WIDTH | 1.600 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES DC LAMP LOAD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE FIRST MOUNTING FACILITY |
APCN | COIL QUANTITY | 1 |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.125 INCHES NOMINAL SECOND MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 8.0 AMPERES DC INDUCTIVE LOAD |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL FIRST MOUNTING FACILITY |
CBME | CUBIC MEASURE | 6.663 CUBIC INCHES |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.000 INCHES NOMINAL SECOND MOUNTING FACILITY |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
CQYJ | MOUNTING FACILITY PATTERN | IN-LINE FIRST MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 4.0 AMPERES DC MOTOR LOAD |
ABHP | OVERALL LENGTH | 1.531 INCHES MAXIMUM |
APNP | DUTY TYPE | CONTINUOUS |
ABKW | OVERALL HEIGHT | 2.720 INCHES MAXIMUM |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 1.540 INCHES NOMINAL SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |