Part Number
Part Number:
NSN:
NIIN:
Item Name:
FILTER , RADIO FREQUENCY INTERFERE
Definition:
AN ITEM DESIGNED TO SUPPRESS UNDESIRED (INTERFERING) FREQUENCIES AND HAVE A MINIMAL EFFECT ON THE DESIRED FREQUENCIES WHEN INSERTED IN AN ELECTRICAL POWER CIRCUIT. EXCLUDES ITEMS WHICH CONSIST OF A SINGLE CAPACITOR, INDUCTOR, RESISTOR, OR DEVICES CONSISTING OF ONLY TWO OR MORE CIRCUIT ELEMENTS OF THE SAME BASIC NAME. EXCLUDES FILTER, LOW PASS AND SUPPRESSOR, IGNITION INTERFERENCE. FOR ITEMS DESIGNED TO BE INSERTED IN A LINE WHICH IS PRIMARILY INTENDED TO CARRY HIGH FREQUENCY WAVES MODULATED WITH SIGNALS, SUCH AS ANTENNA LEAD-IN, SEE FILTER, BAND SUPPRESSION AND FILTER, BAND PASS. SEE ALSO LIMITER, ELECTRICAL NOISE.
CAGE Information
Code | Company |
---|---|
56289 | SPRAGUE ELECTRIC CO WORLD HQS |
Federal Supply Class
Title
FILTERS AND NETWORKS
Inclusions:
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 2ND RADIO INTERFERENCE |
AFSV | AVERAGE LIFE RATING IN HOURS | 1000.0 |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 7.0 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.937 INCHES NOMINAL |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 7.0 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TURRET INPUT |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 3 TURRET OUTPUT |
CQRG | BODY MATERIAL | METAL |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AFGA | OPERATING TEMP RANGE | -65.0/+125.0 DEG CELSIUS |
ABHP | OVERALL LENGTH | 3.312 INCHES NOMINAL |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
ADAQ | BODY LENGTH | 2.500 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 1ST RADIO INTERFERENCE |
ADAU | BODY HEIGHT | 0.875 INCHES NOMINAL |
ADAT | BODY WIDTH | 2.000 INCHES NOMINAL |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 500.0 MILLIVOLTS AC 3RD RADIO INTERFERENCE |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.187 INCHES NOMINAL |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 9.0 3RD RADIO INTERFERENCE |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 125.0 VOLTS AC 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE |