Part Number
Definition:
A RESISTOR IN WHICH A SLIDING OR ROLLING CONTACT MOVES OVER AN EXPOSED AREA OF THE RESISTIVE ELEMENT TO CHANGE THE OHMIC VALUE OF THE OUTPUT. THE FUNCTIONAL TOLERANCE (LINEARITY), IF GIVEN, OF THE OUTPUT IS GREATER THAN PLUS OR MINUS 1 PERCENT ON LINEAR OUTPUTS. SPECIFIED OUTPUTS SUCH AS SINE, COSINE, TANGENT, ETC., SHALL BE CONSIDERED TO BE PRECISION. FOR ITEMS HAVING MANUALLY POSITIONED TAPS DESIGNED TO BE SET AND FIXED PRIOR TO USE, SEE RESISTOR, ADJUSTABLE. FOR ITEMS WITH STEP BY STEP VARIATION, SEE RHEOSTAT AND RESISTOR, STEP BY STEP. FOR TANDEM-MOUNTED ITEMS DESIGNED TO FUNCTION TOGETHER AS AN ATTENUATOR (AND RATED ACCORDINGLY), SEE ATTENUATOR, VARIABLE. EXCLUDES RESISTOR (1), VARIABLE, WIRE WOUND, NONPRECISION; RESISTOR (1), VARIABLE, NONWIRE WOUND PRECISION; AND RESISTOR (1), VARIABLE, WIRE WOUND, PRECISION.
CAGE Information
Code | Company |
---|---|
84048 | VERNITRON CORP VRN INTERNATIONAL DIV |
Federal Supply Class
Title
RESISTORS
Inclusions:
INCLUDES VARISTORS; RESISTIVE BALLAST TUBES; RHEOSTATS; RESISTOR NETWORKS; RESISTOR MOUNTING HARDWARE; THERMISTORS.
Exclusions:
EXCLUDES RESISTANCE WIRE.
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE TWO ROWS |
AAPN | SECTION QUANTITY | 1 |
CRSX | ACTUATOR TRAVEL CONTROL FEATURE | STOPS |
TTQY | TERMINAL TYPE AND QUANTITY | 3 PIN |
AXGY | MOUNTING METHOD | TERMINAL |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -20.0/+20.0 SINGLE SECTION |
ABKW | OVERALL HEIGHT | 0.672 INCHES NOMINAL |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 150.0 SINGLE SECTION |
AEDZ | SHAFT BEARING TYPE | SLEEVE |
ABJT | TERMINAL LENGTH | 0.312 INCHES NOMINAL |
ADAQ | BODY LENGTH | 0.230 INCHES MINIMUM AND 0.260 INCHES MAXIMUM |
AEFD | ACTUATOR TYPE | FLUSH DRIVE WITH SLOT-HOLE |
AAQL | BODY STYLE | RECTANGULAR |
AEFH | EFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION | 240.0 NOMINAL |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0.100 NOMINAL INCHES |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 200.000 PERCENT, RATED AMPERES C AND BETTER FLOORING |
ABHP | OVERALL LENGTH | 0.245 INCHES NOMINAL |
AEFL | MAXIMUM RUNNING TORQUE | 5.00 INCH-OUNCES |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 85.0 SINGLE SECTION |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0.200 INCHES NOMINAL |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0.5 7TH SECONDARY QUALITY |
CQCK | ROTARY ACTUATOR TRAVEL IN ANGULAR DEG | 260.0 NOMINAL |
CBBL | FEATURES PROVIDED | HUMIDITY PROOF |
AEFK | MAXIMUM STARTING TORQUE | 5.00 INCH-OUNCES |
CSDL | STANDARD TAPER CURVE PER SECTION | A SINGLE SECTION |
CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | -100.0/+100.0 SINGLE SECTION |
ADAT | BODY WIDTH | 0.280 INCHES MINIMUM AND 0.300 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 0.290 INCHES NOMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0.100 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.350 INCHES MINIMUM AND 0.370 INCHES MAXIMUM |